English
20
䢇
After stapling:
1)
disconnect air hose from the Stapler;
2)
remove all staples from the Stapler;
3)
supply 5 – 10 drops of Hitachi pneumatic tool lubricant into the air plug on the
Stapler; and
4)
open the petcock on the air compressor tank to drain any moisture.
ADJUSTING THE STAPLING DEPTH
To assure that each staple penetrates to the same depth, be sure that:
1)
the air pressure to the Stapler remains constant (regulator is installed and working
properly), and
2)
the Stapler is always held firmly against the workpiece.
If staples are driven too deep or shallow into the workpiece, adjust the stapling in the
following order.
1
DISCONNECT AIR HOSE FROM STAPLER.
2
If staples are driven too deep, turn the
adjuster to the shallow side.
Adjustments are in half-turn increments.
3
If staples are driven too shallow, turn the
adjuster to the deep side.
Stop turning the adjuster when a suitable
position is reached for a stapling test.
Disconnect
air hose
1 5
Adjuster
Too Deep
Turn Adjuster
Flush
Too Shallow
Turn Adjuster
Flush