CONTROL AND FUNCTION
29
TIMER
LAMP
BLINKING
LD301
BLINKING
CODE
MEANING
O
U
TD
O
O
R
4 times
6 times
OH thermistor temperature rise
4 times
7 times
Abnormal outdoor thermistor
4 times
16
times
Hign load stop
4 times
9 times
Communication error
4 times
10 times
Abnormal power source
4 times
11 times
Fan stop for strong wind
4 times
12 times
Fan motor fault
4 times
13 times
EEPROM reading error
4 times
14 times
Active converter defective
4 times
15 times
Abnormal PWB circuit
07
I
12
I
13
I
14
I
06
I
10
I
11
I
09
I
15
I
1
6
I
Содержание MULTIZONE RAK-25RXE
Страница 1: ...TECHNICAL CATALOGUE MONO SPLIT RAK 25RXE RAK 35RXE RAK 50RXE RAC 25WXE RAC 35WXE RAC 50WXE ...
Страница 8: ...DIMENSIONAL DATA 6 2 3 WALL TYPE RAC 50WXE ...
Страница 19: ...WIRING DIAGRAM 17 7 WIRING DIAGRAM 7 1 RAK 25RXE RAK 35RXE RAK 50RXE ...
Страница 20: ...WIRING DIAGRAM 18 7 2 RAC 25WXE RAC 35WXE RAC 50WXE ...
Страница 39: ...TC ERP Model 2019 02 INDOOR OUTDOOR RAC 25WXE RAC 35WXE RAC 50WXE RAK 25RXE RAK 35RXE RAK 50RXE ...