OPTION LIST
10-13
Example of wiring connection to Card Key Unit will be as below (reference only)
CARD KEY UNIT (Prepared by INSTALLER)
AIR CONDITIONER INDOOR PCB
•
CONNECTION EXAMPLE
i. Pin No. 3 of DIP SWITCH is set to OFF position (HI Input Active) for Dry Contact Type a
ii. Pin No. 3 of DIP SWITCH is set to ON position (LO Input Active) for Dry Contact Type b
Please refer to the actual manual supplied with the optional connecting cords SPX-WDC2/WDC3 for more details.
AC
POWER
SUPPLY
①
Connecting Cord to PCB:
SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
②
Contact with sleeve
CN6 or CN9
(Refer to Table 1)
DIP SW Label
(Refer to Table 1)
Dry contact
Card sensor
indicator
Window
Close: ON
Open: OFF
Window
Close: ON
Open: OFF
Card key unit
Insert Card: ON
Remove Card: OFF
Indoor unit
PWB
Connection
Connection
SERIAL CONNECTION
All SW
ON
→
OPERATION
Connecting cord to PCB
Accessory# SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
Window
Close: OFF
Open: ON
Window
Close: OFF
Open: ON
Card key unit
Insert Card: OFF
Remove Card: ON
Indoor unit
PWB
Connection
Connection
PARALLEL CONNECTION
All SW
OFF
→
OPERATION
Connecting cord to PCB
Accessory# SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
Содержание MULTIZONE RAD-18QPE
Страница 8: ...DIMENSIONAL DATA 2 5 2 1 4 FLOOR TYPE RAF 25RXE 35RXE 50RXE ...
Страница 9: ...DIMENSIONAL DATA 2 6 2 1 5 CEILING CASSETTE TYPE RAI 25RPE 35RPE 50RPE 60RPE ECPP ...
Страница 10: ...DIMENSIONAL DATA 2 7 2 1 6 DUCT TYPE RAD 18QPE 25RPE 35RPE Unit mm ...
Страница 11: ...DIMENSIONAL DATA 2 8 2 1 7 DUCT TYPE RAD 50RPE 60RPE ...
Страница 27: ...TC_ERP MULTI R32 2019 00 ...