17
QM00612-1
RS-232C Communication / Network command table
Names
Operation Type
Header
Command Data
CRC
Action
Type
Setting code
Power
Set
Turn off
BE EF
03
06 00
2A D3
01 00
00 60
00 00
Turn on
BE EF
03
06 00
BA D2
01 00
00 60
01 00
Get
BE EF
03
06 00
19 D3
02 00
00 60
00 00
[Example return]
00 00
01 00
02 00
[Off]
[On]
[Cool down]
Input Source
Set
COMPUTER IN1
BE EF
03
06 00
FE D2
01 00
00 20
00 00
COMPUTER IN2
BE EF
03
06 00
3E D0
01 00
00 20
04 00
HDMI1
BE EF
03
06 00
0E D2
01 00
00 20
03 00
HDMI2
BE EF
03
06 00
6E D6
01 00
00 20
0D 00
VIDEO
BE EF
03
06 00
6E D3
01 00
00 20
01 00
USB TYPE A
BE EF
03
06 00
5E D1
01 00
00 20
06 00
LAN
BE EF
03
06 00
CE D5
01 00
00 20
0B 00
USB TYPE B
BE EF
03
06 00
FE D7
01 00
00 20
0C 00
Get
BE EF
03
06 00
CD D2
02 00
00 20
00 00
Error Status
Get
BE EF
03
06 00
D9 D8
02 00
20 60
00 00
[Example return]
00 00 01 00 02 00 03 00
[Normal] [Cover error] [Fan error] [Lamp error]
04 00 05 00 07 00 08 00
[Temp error] [Air flow error] [Cold error] [Filter error]
MAGNIFY
Get
BE EF
03
06 00
7C D2
02 00
07 30
00 00
Increment
BE EF
03
06 00
1A D2
04 00
07 30
00 00
Decrement
BE EF
03
06 00
CB D3
05 00
07 30
00 00
FREEZE
Set
NORMAL
BE EF
03
06 00
83 D2
01 00
02 30
00 00
FREEZE
BE EF
03
06 00
13 D3
01 00
02 30
01 00
Get
BE EF
03
06 00
B0 D2
02 00
02 30
00 00
PICTURE
MODE
Set
NORMAL
BE EF
03
06 00
23 F6
01 00
BA 30
00 00
CINEMA
BE EF
03
06 00
B3 F7
01 00
BA 30
01 00
DYNAMIC
BE EF
03
06 00
E3 F4
01 00
BA 30
04 00
BOARD(BLACK)
BE EF
03
06 00
E3 EF
01 00
BA 30
20 00
BOARD(GREEN) BE EF
03
06 00
73 EE
01 00
BA 30
21 00
WHITEBOARD
BE EF
03
06 00
83 EE
01 00
BA 30
22 00
DAYTIME
BE EF
03
06 00
E3 C7
01 00
BA 30
40 00
PHOTO
BE EF
03
06 00
73 F5
01 00
BA 30
05 00
Get
BE EF
03
06 00
10 F6
02 00
BA 30
00 00
[Example return]
00 00
01 00
04 00
10 00
05 00
[Normal] [Cinema] [Dynamic] [Custom] [PHOTO]
20 00
21 00
22 00
40 00
[BOARD(BLACK)] [BOARD(GREEN)] [WHITEBOARD] [DAY TIME]
41 00
[DICOM SIM.]
BRIGHTNESS
Get
BE EF
03
06 00
89 D2
02 00
03 20
00 00
Increment
BE EF
03
06 00
EF D2
04 00
03 20
00 00
Decrement
BE EF
03
06 00
3E D3
05 00
03 20
00 00
BRIGHTNESS
Reset
Execute
BE EF
03
06 00
58 D3
06 00
00 70
00 00
RS-232C Communication / Network command table
(continued on next page)