![Hitachi HUS VM Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969210.webp)
For details, see
Configuring Server Priority Manager by specifying LDEVs
and WWNs or iSCSI names of HBAs on page 5-66
Note:
The WWN of a host bus adapter connected to a port is required when
specifying the port with CCI and setting SPM. Since the WWN of an HBA
connected to a NAS Platform port cannot be obtained, the SPM setting with
specifying these port types is not available.
Configuring Server Priority Manager by specifying ports and WWNs
of HBAs
This section describes operations for configuring Server Priority Manager by
specifying a port and a WWN of a host bus adapter.
•
Controlling the priority of I/O operations in storage systems on servers on
•
Using and managing Server Priority Manager on page 5-57
•
Setting SPM names for WWNs and registering them to the SPM group on
•
Configuring Server Priority Manager by specifying ports and WWNs of
•
Cautions about using Server Priority Manager on page 5-63
•
Cautions when using host groups after registering them in SPM groups
Controlling the priority of I/O operations in storage systems on servers
To control server performance, specify the I/O operation priority (prioritized
or non-prioritized), the threshold (one value for each storage system), and
the upper limit (one value for each non-prioritized WWN) for host bus
adapters on a host. Set a host bus adapter with higher priority as a prioritized
WWN, and set a host bus adapter with lower priority as a non-prioritized
WWN. By adjusting the upper limit or threshold to an appropriate value, you
can maintain the number of accesses or the amount of data to be transferred
to a storage system at a higher level on a prioritized server.
Table 5-3 Priority to be set by specifying a port and a WWN of an HBA, and
control of server performance
Priority
Server performance
Non-prioritized
Controls server performance based on the upper limit. The upper limit
is set for each non-prioritized WWN.
The upper limit suppresses the number of accesses to a storage
system, or the amount of data to be transferred. Monitoring
information can be displayed according to the combination of a port
and a WWN of a host bus adapter.
Prioritized
Controls server performance based on the threshold. One threshold is
set for each storage system, but it cannot be set for each prioritized
WWN.
5-56
Provisioning operations with CCI
Command Control Interface User and Reference Guide
Содержание HUS VM
Страница 10: ...x Command Control Interface User and Reference Guide ...
Страница 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Страница 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Страница 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Страница 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Страница 277: ... 1 UR 2x2 Data replication operations with CCI 6 53 Command Control Interface User and Reference Guide ...
Страница 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Страница 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Страница 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Страница 529: ...Command Control Interface User and Reference Guide ...