D C I N V E R T E R C O M P R E S S O R C R I T E R I A
PAGE:12/32
(8) The main electric circuit should be equipped with fuse or breaker.
(9) Refrigerant should be charged from the end of condenser of refrigerating systems. Never
Charge refrigerant to the compressor directly.
The refrigerant should always be charged in liquid state. When the refrigerant is charged in
gas state,
The percent component will possibly be changed. Do not recharge with the
remaining refrigerant in the system when leakage happened. Because the percent component of
the refrigerant in the unit system had possibly been changed.
(10) Temperatures within systems during stable compressor operation should not be less than
-35℃ to prevent wax precipitation from the oil.
(
11) Compressor mounting
Rubber grommets are designed soft to provide the noise isolation and to lessen vibration
Energy transmission. Stud bolt should be designed to provide sufficient clearance for noise and
vibration isolation and to prevent compressor from coming off its mount.
(12) The units of refrigerating system should be connected to earth.
(13) There should be adequate clearance between the OD23-under-surface of Push-Nut and the
upper surface of rubber grommets.
(14) SHEC will not take any responsibility against accident that is caused by the accessories
equipped by yourselves.
(15) The hermetic terminals of compressor should not be inserted slantingly and not be applied
twisting force after inserting so as to avoid reducing of terminal fixed force.
Содержание HIGHLY WHP08750VCDNC9AU
Страница 18: ...PAGE 16 32 ...
Страница 19: ...PAGE 17 32 ...
Страница 20: ...PAGE 18 32 ...
Страница 21: ...PAGE 19 32 ...
Страница 22: ...PAGE 20 32 ...
Страница 23: ...PAGE 21 32 ...
Страница 24: ...PAGE 22 32 ...
Страница 25: ...PAGE 23 32 ...
Страница 26: ...PAGE 24 32 ...
Страница 27: ...PAGE 25 32 ...
Страница 30: ...PAGE 28 32 ...
Страница 33: ...PAGE 31 32 SHANGHAI HIGHLY ELECTRICAL APPLIANCES CO LTD WHP08750VCD COMPRESSOR PREFORMANCE CURVE to tc ...
Страница 34: ...PAGE 32 32 ...