English
12
CAUTION: After long time of use, the front cover becomes hot.
Therefore, be careful not to burn your hands.
OIL FILLING
CAUTION: Prior to oil filling, always
disconnect the plug form the
receptacle.
Since an oil chamber is built in this Hitachi
Demolition Hammer, it can be used for
approximately 20 days without supplying
lubricating oil, assuming that the Hammer is
used continuously 3 – 4 hours daily.
Fill oil into the oil tank as described below
before using this Hammer. (See Figs. 5 and 6)
1. Just before no oil is visible in the oil gauge
window when the power tool is held
upright, fill oil without fail.
2. Before filling oil, use the provided wrench
to remove the oil gauge.
Be careful not to lose the rubber packing
attached below the oil gauge.
3. Check the oil level once a day, confirming
that oil is filled.
4. After filling with oil, securely clamp the oil
gauge.
NOTE:
As an optional accessory, oil for the Hitachi
Electric Hammer (one liter) is sold separately.
Use this oil when oil in the tank is depleted.
Fig. 5
Oil Gauge
Check the oil quantity
by holding the body
upright.
15/128"
(3 mm)
Fig. 6
Resupply oil when the oil level drops
to less than approx. 15/128" (3 mm)
Содержание H 65SC
Страница 42: ...42 Español ...