2
.
On the storage system at the primary site, suspend the GAD pairs by
specifying the primary volume.
pairsplit -g oraHA -r -IH0
3
.
Confirm that the pair status of P-VOLs of GAD pairs has changed to
PSUS(Local) and the pair status of the S-VOLs has changed to
SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
4
.
Power off the storage system at the secondary site.
Powering on the secondary storage system
1
.
Power on the storage system at the secondary site.
2
.
Confirm that the primary and secondary storage systems and the external
storage system for the quorum disk do not have any blocked parts.
If any parts are blocked, recover them.
3
.
Check for SIMs about path blockage, and delete the SIMs.
4
.
Confirm that the pair status of the P-VOLs of the GAD pairs is PSUS(Local)
and that the pair status of the S-VOLs is SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
5
.
On the storage system at the primary site, resynchronize the GAD pairs
by specifying the primary volume.
pairresync -g oraHA -IH0
6
.
Confirm that the pair status of the P-VOLs and S-VOLs of the GAD pairs
has changed to PAIR (Mirror (RL)).
pairdisplay -g oraHA -fcxe -IH0
7
.
Using the alternate path software, resume I/O from the servers to the
storage system at the secondary site.
Planned power off/on of the external storage system (I/O
at primary site)
Powering off the external storage system (I/O at primary site)
1
.
Direct server I/O to the storage system at the primary site.
Using the alternate path software, stop I/O from the servers to the
storage system at the secondary site.
2
.
On the storage system at the primary site, suspend the GAD pairs by
specifying the primary volume.
pairsplit -g oraHA -r -IH0
3
.
Confirm that the pair status of P-VOLs of the GAD pairs has changed to
PSUS(Local) and that the pair status of the S-VOLs has changed to
SSUS(Block).
pairdisplay -g oraHA -fcxe -IH0
4
.
On the primary and secondary storage systems, disconnect the quorum
disks.
Planned outage of global-active device storage systems
7-3
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Содержание G1000
Страница 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 60: ...2 22 System requirements Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 80: ...3 20 Planning for global active device Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 128: ...4 48 Configuration and pair management using CCI Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Страница 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...