Getting Started: Installation and Adjustment Procedure
ATTACHING THE FT-01B:
Attach the FT-01B:
The FT-01B has to be attached on the same surface
of the image. Don’t attach outside of the whiteboard
or on the frame.
The FT-01B has to be above and center of the
image.
The distance of 2"- 4" is needed between the
bottom of the FT-01B and top of the image.
The distance of 0.5" or more is recommended
between the bottom of the upper-frame and the top
of the FT-01B, to prevent the cover being blocked by
the frame when it’s removed.
Plug the cable FT-01B and Option Port:
Connect the FT-01B and Projector’s Option port
with the mini-USB cable to supply the power. Use
Phillips screwdriver to remove the cover of the
Option port.
Go to ADVANCED MENU -> IWB -> IWB SETUP
and check if FINGER TOUCH is set to ON.
ATTACH FT-01B:
Attach the ADJUSTING BAR:
Attach the Adjusting-Bar at the bottom right and left
corners of the image. Surface with the 3 white-dots
has to face upward.
Set adjusting knobs:
Set all 3 adjusting knobs (1) & (2) & (3) so that these
protrude about 0.3" from the case.
Show the CAMERA VIEW:
Go to ADVANCED MENU -> IWB -> IWB SETUP->
CAMERA VIEW
OK
Bad
Bad
Mini USB cable
Adjustment bar
CAMERA VIEW
(image from built-in camera)
0.3" from case
Option