PJ-LC9(C12H)
6-11 Regarding the indicator lamps
Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the mean-
ings as described in the table below. Please respond in accordance with the instructions with in the table.
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Lighting
In Orange
Turned
off
Turned
off
The projector is in a standby state.
Blinking
In Green
Turned
off
Turned
off
The projector is warming up.
Please wait.
Lighting
In Green
Turned
off
Turned
off
The projector is in an on state.
Ordinary operations may be performed.
Blinking
In Orange
Turned
off
Turned
off
The projector is cooling down.
Please wait.
Blinking
In Red
(discre-
tionary)
(discre-
tionary)
The projector is cooling down. A certain error has been detected.
Please wait until the POWER indicator finishes blink, and then perform the proper
response measure using the item descriptions below as reference.
Blinking
In Red
or
Lighting
In Red
Lighting
In Red
Turned
off
The lamp does not light, and there is a possibility that interior portion has
become heated.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suffi ciently cooled down, please make confi rmation of the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment, please change the lamp by
referring to the section "Lamp"
Blinking
In Red
or
Lighting
In Red
Blinking
In Red
Turned
off
The lamp cover has not been properly fi xed (attached).
Please turn the power off, and allow the unit to cool down at least 45 minutes. After
the projector has suffi ciently cooled down, please make confi rmation of the attachment
state of the lamp cover. After performing any needed maintenance, turn the power on
again.
Blinking
In Red
or
Lighting
In Red
Turned
off
Blinking
In Red
The cooling fan is not operating.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suffi ciently cooled down, please make confi rmation that no foreign matter
has become caught in the fan, etc. and then turn the power on again.
If the same indication is displayed after the treatment, please replace a fan.
Blinking
In Red
or
Lighting
In Red
Turned
off
Lighting
In Red
There is a possibility that the interior portion has become heated.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suffi ciently cooled down, please make confi rmation of the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment, please set the HIGH at the
FAN SPEED of the item SERVICE of the OPTION menu.
Lighting
In Green
Alternative
blinking in Red
There is a possibility that the interior portion has become overcooled.
Please use the unit within the usage temperature parameters (5°C to 35°C). After the
treatment, resent the power to ON.
If the same indication is displayed after the treatment, please make sure the wire
connection of the connectors E301 and E302 on the PWB assembly MAIN.
Lighting
In Green
Simultaneous
blinking in Red
It is time to clean the air fi lter.
Please immediately turn the power off, and clean or change the air fi lter referring to the
section "Air Filter". After cleaning or changing the air fi lter, please be sure to reset the
fi lter timer. After the remedy, reset the power to ON.
If the same indication is displayed after the treatment, please make sure that the panel
duct assembly is assembled correctly. If it still does not recover, replace a cooling fan,
especially the DC FAN(PANEL B).
NOTE
• When the interior portion has become overheated, for safety purposes, the power source is automati-
cally turned off, and the indicator lamps may also be turned off. In such a case, press the “ ” (OFF) side of the
power switch, and wait at least 45 minutes. After the projector has suffi ciently cooled down, please make con-
fi rmation of the attachment state of the lamp and lamp cover, and then turn the power on again.
Содержание EDPJ32
Страница 34: ...34 PJ LC9 C12H ...
Страница 51: ...51 PJ LC9 C12H 12 Connector connection diagram Connector connection diagram CN103 ...
Страница 55: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 1 C12H ...
Страница 56: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 2 C12H ...
Страница 57: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 3 C12H ...
Страница 58: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 4 C12H ...
Страница 59: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 5 C12H ...
Страница 60: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 6 C12H ...
Страница 61: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 7 C12H ...
Страница 62: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 8 C12H ...
Страница 63: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 9 C12H ...
Страница 64: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 10 C12H ...
Страница 65: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 11 C12H ...
Страница 66: ...MEMO ...
Страница 68: ...QR65311 Digital Media Division Printed in Japan JE PJ LC9 YK No 0556 ...