Section 5 - System Operation Manual
(E-Compact ATSC Transmitters - EC701HP thru EC708HP)
Manual Rev. 0.0 - August 2016
5-46
System Alarms
ALARM MESSAGE
ALARM DESCRIPTION
ACTION THAT FOLLOWS
Phase Loss!
Main Breaker is disconnected.
Check Main Breaker OFF.
Get in contact with Hitachi Kokusai
Linear's technical support service.
Output Power Zero!
Indication that the transmitter is
programmed, but there is no
output power
Check the Power Meter Dir. Coupler
Check the power reading at the PC
controls.
+15V Eqp. Fail!
Failure on the +15V equipment
power supply.
Check AC unit.
+8V Eqp. Fail!
Failure on the +8V equipment
power supply.
Check AC unit.
+50V Eqp. Fail!
Failure on the +50V equipment
power supply.
Check AC unit.
Drawers Alarms!
Failure on the RF Power Drawer
Via LCD check which RF Power Drawer
listed is as the failure one.
Access: Main Menu - System Alarms/Log
–
Drawers Alarms.
All PA Fail!
Indication that the all PA´s of the
power drawer are damaged. This
alarm there is only in the
EC701HP.
Get in contact with Hitachi Kokusai
Linear's technical support service.
Driver PA Fail!
Indication that the driver of the
power drawer are damaged. This
alarm there is only in the
EC701HP.
Get in contact with Hitachi Kokusai
Linear's technical support service.
Remote Ctrl Fail!
Communication failure between
exciter and Remote Control
drawer.
Check the physical connection
between exciter and Remote Control.
These connections are located on the
exciter rear panel (green connector), on
the other end, at the rear panel of the
Remote Control (DB-9 connector).