5-14
Section 5 - System Operation Manual
(E-Compact ATSC Transmitters - EC701HP thru EC708HP)
Items on the
SETUP menu
Description
Power Setup
Program the RF output power level
Turn ON and turn OFF the ALC (Automatic Level Control)
Mute the or not the RF power output on the event of absence of
Transport Stream
Transmitter Setup
Select local or remote the transmitter output level control.
Image Frequency
Suppression
TX Balance, eliminated the image frequencies band
LO Leakage
Suppression
Reduces the LO undesirable spurious
Pre-Correction
Enable and Disable the pre-correction circuitry
Turn ON and turn OFF the modulation
Modulation Settings
ATSC pilot level configuration (pilot level programming between
2.048 ~ +511 )
Time and Date Setup Set time and date
Password Setup
Password configuration
Transport Stream
Input
Configure three parameters with respect to the 2 TS inputs:
- TS input: Selects with one is preferable
- Mode: Automatic (automatically switches in the case one fails) /
Manual (does not switch even if it fails)
- Hold: On (hold the last input even if the preferable input stopped
failing) / Off (go back to the preferable input if has stopped failing)
Alarms Mask
Enable or disable conditions to generate alarms.
USB Setup
Selects one of three USB ports available on the 8001:
- Device Rear / Device Frontal: PC software GUI8001
- Host Frontal: USB flash drive for software upgrade
USB Host Access
Setup
With USB Host Frontal selected use this menu and follow further
instructions to make a software upgrade
Crest Factor
Reduction
Configure Crest Factor parameters to reduce the Peak to Average
Power Ratio in order to improve intermodulation on PA output at the
expense of MER degradation
Clock Reference
Set the priority list for exciter time base reference:
- User cal (free running): internal OCXO without a reference (+/-
50ppb)
- Internal GPS*: plug the antenna cable at the rear panel
- External 10 MHz
- External 1PPS
- Incoming TS: this mode is useful for M/H since pre-processor and
post-processor must be in the same time base.
Restore Web
Password to Default
Reset web page user name and password to default values. User:
user
Password: linear
Transistor Aging
Adjustment
Allows you to send the current settings for the power amplifiers.
The values are pre-set at the factory.
PA Temperature Control
It allows you to set the operating temperature of the power amplifiers
drawer.
Manual Rev. 0.1 - February 2018