background image

WARNING 

 

PIPING & WIRING

Concern/Alarm

Possible Consequences

Connect the power supply cable correctly. 

(see page 13) 

If the power supply is installed incorrectly, 

electric shock or fire to the machinery can 

occur. 

Do not bend or pull the power supply cable or 

lead wires of the Vortex Blower. 

Bending or pulling wires can lead to electric 

shock or fire to the machinery. 

Do not put any the power supply cable or lead 

wires between machinery. 

Installing the power supply cable or lead 

wires between machinery can lead to electric 

shock or fire to the machinery. 

Do not touch the terminals during 

measurement of the insulation resistance. 

Touching the terminals can lead to electric 

shock. 

Properly trained personnel should wire the 

Vortex Blower in accordance with electrical 

equipment standards. 

Failure to wire in accordance with the 

standards and/or utilizing improperly trainer 

personnel can lead to burn out of the motor or 

fire to the machinery. 

Installation of an overload protector is 
approved in accordance with electrical 

equipment standards (overload protector is not 

included on theVortex Blower).    Install the 

overload protector in the power supply circuit 

of the Vortex Blower (see page 13). 

Failure to install an overload protector can 

lead todamage to the Vortex Blower, burn out 

of the motor or fire to the machinery. 

Install a ground connection prior to using the Vortex 

Blower. Properly ground (Class 3 ground) the 

equipment. 

Installing a ground connection properly will 

prevent accidents due to current leakage caused by 

electric insulation deterioration. 

Install an independent earth leakage (ground) 

circuit breaker prior to using the Vortex 

Blower. 

Installing an earth leakage (ground) circuit 

breaker will prevent accidents due to current 

leakage caused by electric insulation 

deterioration. 

Install an independent electromagnetic switch 

in the power supply ciruit as protection for the 

Vortex Blower. 

Failure to install an electromagnetic switch 

can lead to damage to the Vortex Blower, 

burn out of the motor or fire to the machinery.

Do not allow the Vortex Blower to inhale any 

type of water. 

Inhaling water can lead to current leaks, 

electric shocks, rusting or bearing damage. 

 

OPERATION 

Concern/Alarm

Possible Consequences

Do not operate the Vortex Blower while the 

terminal box cover is removed. 

Operating while the terminal box cover is 

removed can lead to electric shock. 

After servicing the Vortex Blower, verify that 

the terminal box cover is properly mounted to 

the case. 

Failure to properly mount the terminal box 

cover can lead to electric shock. 

During operation, do not approach or touch 

any of the rotating parts of the Vortex Blower.

Touching any of the rotating parts during 

operation can lead to personal injury. 

If a power loss occurs, turn off the power 

supply. 

Turning off the power supply prevents 

personal injury. 

Do not touch the Vortex Blower during 

operation, as excessive heat is generated. 

Touching the hot Vortex Blower can lead to 

personal injury and burns. 

  Do not touch the Vortex Blower if the power 

supply is still ON. This applies even if the 

Vortex Blower is stopped. 

The Vortex Blower may suddenly start, 

resulting in an personal injury or electric 

shock. 

 
 

 

 

 

- 5 -

Содержание E-U Series

Страница 1: ...rtex Blower After reading this instruction manual please keep it on hand for future reference REQUEST This instruction manual should be delivered to the personnel operating the HITACHI Vortex Blower VB 060 E2 CONTENTS Chapter Description Page 1 SAFETY INFORMATION 2 2 PRE INSTALLATION PROCEDURE 7 3 INSTALLATION 9 4 WIRING 13 5 START UP 17 6 OPERATION AND DAILY INSPECTION 18 7 SECTION DRAWING OF VOR...

Страница 2: ... alert symbol is used to alert personnel of hazards of extreme danger The safety alert symbol and the word WARNING will precede all safety messages The definition of WARNING is described below WARNING Serious injury may occur if any WARNING instructions are not followed All safety messages do the following 1 Identify a hazard 2 Give an explanation for reducing the chances of injury 3 Detail the co...

Страница 3: ...d Vortex Blower Using a damaged Vortex Blower can lead to personal injury fire to the machinery etc Do not make any modifications to the Vortex Blower Hitachi does not take any responsibility for any modifications made to the Vortex Blower Do not place any obstacles in front of the nameplate of the Vortex Blower Placing obstacles in front of the Vortex Blower nameplate will prevent easy access to ...

Страница 4: ... or explosion Avoid using the Vortex Blower in a small or sealed room A small or sealed room will result in excessive heat generated by the Vortex Blower Do not touch the Vortex Blower casing during operation as excessive heat is generated Touching the Vortex Blower during operation will lead to personal injury and burns Do not cover the Vortex Blower Covering or storing the Vortex Blower with com...

Страница 5: ... due to current leakage caused by electric insulation deterioration Install an independent earth leakage ground circuit breaker prior to using the Vortex Blower Installing an earth leakage ground circuit breaker will prevent accidents due to current leakage caused by electric insulation deterioration Install an independent electromagnetic switch in the power supply ciruit as protection for the Vor...

Страница 6: ...jury and burns Perform daily inspection of the Vortex Blower Failure to perform daily inspection can lead to damage the Voltex Blower REPAIR Concern Alarm Possible Consequences Properly trained personnel should perform all repairs of the Vortex Blower Utilizing improperly trained personnel can lead to personal injury electric shock and fire to the machinery Turn off the power supply before perform...

Страница 7: ...near any corrosive liquids corrosive gases and any inflammable or explosive gases see page 4 2 High Starting Frequency a High starting frequency will lead to motor damage NOTE The permissible starting frequency varies depending on the operating conditions Please contact the local Hitachi distributor for more details 3 Operable Range Do not use the Vortex Blower if scheduled performance is not with...

Страница 8: ...00 450 500 550 Volume cfm m 3 min Exaust temperature rise F K VB 004 S E U VB 007 S E U VB 019 S E U VB 030E U VB 060 E2 VB 080 E2 VB 110 E2 VB 040 E2 60 Hz 2 83 5 66 8 49 1 42 4 25 7 08 9 91 12 74 15 57 11 33 14 16 27 8 55 6 83 3 111 1 138 9 VB 002SE U VB 001SE U VB 003SE U NOTES 1 Suction air temperature must be added to calculate the exhaust temperature 2 These temperature rise values are for r...

Страница 9: ...ig 3 2 VB 060 E2 VB 080 E2 Motor hooks on housing Do not use to lift See fig 3 1 Eyebolt on the bracket Use eyebolt See fig 3 2 VB 110 E2 Motor hooks on housing Do not use to lift See fig 3 1 Eyebolt on the bracket Eyebolt and lope See fig 3 3 NOTES Use the eyebolt on the motor housing for Vortex Blower model VB 019 S E U and VB 030E U Use the eyebolt on the blower casing for Vortex Blower model V...

Страница 10: ...aller In these instances verify that blower unit faces downward see Vertical Installation I below Do not perform vertical installation VB 030E U or larger Do not perform vertical installation as shown in Vertical Installation II Upper Part Upper Part Lower Part Lower Part Motor Unit Blower Unit Motor Unit Blower Unit Blower Unit Horizontal Installation Vertical Installation I Vertical Installation...

Страница 11: ...e port Align the centers of the pipe correctly The flange size of Vortex Blower is shown on the table to the right Please see the illustration below Fig 3 4 detailing how to properly connect the hose to the Vortex Blower Install a pressure gauge in order to check the maximum operating static pressure Mount the pressure gauge in one of the two thread holes provided for pressure measurement on the l...

Страница 12: ...arting current The starting torque will cause a developing clearance in the tolerances between the impeller and the shaft which can lead to motor burnout or impeller contact this will affect the life of the ball bearing During unavoidable intermittent operation a changeover valve system can be installed to prevent this event from occurring see the illustrations below To operate the Vortex Blower w...

Страница 13: ...verify that there are no large voltage drops Be sure to use a larger wire gage if power line length exceeds 66 ft 20m 4 In the case that an inverter is utilized with the power supply of the Vortex Blower use the recommended wire gage for the inverter NOTE An inverter can only be applied to 3 phase model Vortex Blowers 5 Use and install an earth leakage ground breaker and an electromagnetic switch ...

Страница 14: ... 003SE U 0 3 2 5 B 1 230 1 7 5 3 AWG14 115 6 0 20 0 VB 004SE U 0 4 1 2 B 1 230 3 0 10 0 AWG14 115 9 4 44 0 VB 007SE U 0 75 1 B 1 230 4 7 22 0 AWG14 115 19 100 0 VB 019SE U 1 9 2 1 2 B 1 230 9 5 50 0 AWG13 1 Phase wiring diagrams for VB 001SE U thru VB 019SE U 4 3 2 1 P 115V 4 3 2 1 P 230V 4 3 2 1 P Thermal Protector Capacitor 4 2 3 1 P Thermal Protector Capacitor P 4 3 2 1 P 115V P 4 3 2 1 P 230V ...

Страница 15: ...12 105 230 11 120 VB 040 E2 3 7 5 B 3 460 5 5 60 AWG9 200 22 168 230 20 200 VB 060 E2 7 5 10 B 3 460 10 100 AWG9 200 31 230 230 28 275 VB 080 E2 9 12 B 3 460 14 138 AWG6 200 43 375 230 41 445 VB 110 E2 15 20 B 3 460 20 223 AWG4 3 Phase wiring diagrams for VB 004E U thru VB 110 E2 3 2 1 9 8 7 460V 6 5 4 1 6 3 5 2 4 9 8 7 200 230V 3 2 1 9 8 7 6 4 5 VB 060 E2 thru VB 110 E2 3 Phase wiring diagrams 20...

Страница 16: ... windings Power will be restored when the thermal protector measures 170 6oF 27oF 77oC 15oC and the motor will resume at full speed See page 14 3 Pilot duty thermal protection In models VB 019SE U and VB 004E U thru VB 030E U the thermal protector must be put in series with the electromagnetic switch The thermal protector opens at 248oF 9oF 120oC 5oC and closes at 170 6oF 27oF 77oC 15oC The electr...

Страница 17: ...he Vortex Blower suction discharge ports coincides with the IN or OUT directional stickers If the rotation direction is reversed change the connections of two of the three power supply cables The rotation direction does not reverse on the 1 phase Vortex Blower 3 Operating Static Pressure and Amperage Current Check Provide a bypass hole that will allow air to escape if the static pressure is greate...

Страница 18: ...oltage o Vortex Blower is operating in a dusty environment that may impair impeller performance o Vortex Blower s operating pressure is higher than the maximum operating pressure o Vortex Blower is operating at no flow or on the dotted portion of performance curve o Vortex Blower has single phased this only applies with a 3 phase motor DAILY INSPECTION 1 Verify that the operating static pressure i...

Страница 19: ...7 SECTION DRAWING OF VORTEX BLOWER Models VB 001SE U thru VB 003SE U Models VB 004E U thru VB 040 E2 Fig 7 1 Fig 7 2 19 ...

Страница 20: ...Models VB 060 E2 thru VB 110 E2 Fig 7 3 20 ...

Страница 21: ...een inhaled causing restriction to the impeller Contact the local Hitachi distributor for repair Vortex Blower is making a droning sound Impeller and the casing come in contact at the side cover Contact the local Hitachi distributor for repair Power supply has been damaged Inspect and fix the power as necessary Phase failure in the power supply Inspect and fix the power as necessary Stator coil is...

Страница 22: ...or repair Stator coil short circuit Vortex Blower is making a droning sound Improper gap spacing between the stator and the coil Contact the local Hitachi distributor for repair If the sound is Metallic there may be impeller contact Contact the local Hitachi distributor for repair Vortex Blower is making unusual or excessive noise If the sound is Rumbling there may be damage to the ball bearing Co...

Страница 23: ... 23 ...

Страница 24: ... the Vortex Blower s specifications below for future reference Model VB Vortex Blower MFG No Installation Date Day month year Start Up Date Day month year Local Hitachi Distributor Phone Primary Contact 24 ...