9. MAINTENANCE [How to Service the Air Compressor]
①
Turn off the power and wait approximately 10
minutes. Next, remove the front door and then
remove the cover of control panel
②
Check that the charge lights of the controller and fan
inverter are off. Check for abnormal overheat,
discoloration, abnormal odor, and contamination.
③
Blow off the dust by dry air
④
During periodical maintenance, re-tighten the
terminals, check the conductor and insulator for
corrosion, and inspect/replace the cooling fan and
smoothing capacitor.
Contact the local HITACHI distributor/master dealer or
representative office for the detail.