background image

 

P

RECAUTIONARY

 M

EASURES

 

XIV

Electrostatic Discharge (ESD)

Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only 
by their edges without any component and pin touching. After removing a board from its 
protective wrapper or from the system, place the board component side up on a 
grounded, static free surface. Use a conductive foam pad if available but not the board 
wrapper. Do not slide board over any surface.

Cooling and Airflow

Please be aware that slots and openings on the front and back side of the chassis are 
designed for ventilation; to make sure reliable operation of your system and to protect it 
from overheating, these openings must not be covered or blocked. The openings should 
never be covered or blocked by placing the product on a bed, sofa, rug, or other similar 
surface. This product should never be placed near or over a radiator or heat register, or in a 
built-in installation unless proper ventilation is provided.

Laser Peripherals or Devices

Use certified and rated Laser Class I for Optical Transceiver product.

Heed safety instructions: 

Before working with the system, whether using this manual or 

any other resource as a reference, pay close attention to the safety instructions. Adhere to 
the assembly instructions in this manual to ensure and maintain compliance with existing 
product certifications and approvals. Use only the described, regulated components 

CAUTION!

ESD 

CAN

 

DAMAGE

 

DRIVES

BOARDS

AND

 

OTHER

 

PARTS

. W

E

 

RECOMMEND

 

THAT

 

YOU

 

PERFORM

 

ALL

 

PROCEDURES

 

AT

 

AN

 ESD 

WORKSTATION

. I

F

 

ONE

 

IS

 

NOT

 

AVAILABLE

PROVIDE

 

SOME

 ESD 

PROTECTION

 

BY

 

WEARING

 

AN

 

ANTI

-

STATIC

 

WRIST

 

STRAP

 

ATTACHED

 

TO

 

CHASSIS

 

GROUND

 -- 

ANY

 

UNPAINTED

 

METAL

 

SURFACE

 -- 

ON

 

YOUR

 

SERVER

 

WHEN

 

HANDLING

 

PARTS

.

CAUTION!

C

AREFULLY

 

ROUTE

 

CABLES

 

AS

 

DIRECTED

 

TO

 

MINIMIZE

 

AIRFLOW

 

BLOCKAGE

 

AND

 

COOLING

 

PROBLEMS

. F

OR

 

PROPER

 

COOLING

 

AND

 

AIRFLOW

OPERATE

 

THE

 

SYSTEM

 

ONLY

 

WITH

 

THE

 

CHASSIS

 

COVERS

* / 

AIR

 

DUCTS

 

INSTALLED

. O

PERATING

 

THE

 

SYSTEM

 

WITHOUT

 

THE

 

COVERS

 / 

AIR

 

DUCTS

 

IN

 

PLACE

 

CAN

 

DAMAGE

 

SYSTEM

 

PARTS

T

O

 

INSTALL

 

THE

 

COVERS

* / 

AIR

 

DUCTS

:

Check first to make sure you have not left loose tools or parts inside the system.

Check that cables, add-in cards, and other components are properly installed.

Attach the covers* / air ducts to the chassis according to the product instructions. 

* May not apply to all systems.

CAUTION!

T

O

 

AVOID

 

RISK

 

OF

 

RADIATION

 

EXPOSURE

 

AND

 / 

OR

 

PERSONAL

 

INJURY

:

Do not open the enclosure of any laser peripheral or device.

Laser peripherals or devices are not serviceable.

Return to manufacturer for servicing.

!

!

!

Содержание DS225

Страница 1: ...achi Advanced Server DS225 Hardware Guide This guide provides the system overview and specifications for Hitachi Advanced Server OS225 includjng hardware component descriptions MK 97HAS013 01 January 2019 ...

Страница 2: ...ess1e1evan1 data and 2 Venfyflg th8 4818000 ll fJ8S IO be held rfl JtreY8CS dew ed Ofothet Wlse processed1naa oRSanee Wllhrelevant laws NotJce on Ex ponControls The tec h llcaldata anc1 tachnol0gylnher81 11Inlhls DoaJm8l 1ImaybeSl tljec stoU S elq Ot1corr rol taws lnokJdlng heU S ExportAdm strationAt J and ns8 90Cl b d tei JU13tl0n8 andmaybest ti ectIOelQX ftot Import regt tations1n Clttwcountne R...

Страница 3: ...iew 1 7 System Front View 1 8 Front Control Panel FCP 1 11 System Back View 1 11 System Back I O 1 12 Power Sub System 1 13 LED Status Definitions 1 13 Front Control Panel LEDs 1 13 BMC Management Port LEDs 1 14 Storage Drive LED 1 15 Enabling the Intel VMD Technology 1 15 Enabling Platform Trusted Technology PTT 1 17 TPM Configuration Settings 1 17 ...

Страница 4: ...ons and the names of the folders menus programs and files Enter type face denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES SIMILAR TO NOTES AND WARNINGS CAUTIONS HOWEVER APPEAR IN CAPITAL LETTERS AND CONTAIN VITAL HEALTH AND SAFETY I...

Страница 5: ...viced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in related chapters to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product a...

Страница 6: ...uppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power system because they serve as the product s main power disconnect Provided with either two independent DC power system or two independent phases from a single power system The enclosure is designed to carry only th...

Страница 7: ...SEPARATE THE SYSTEM FROM THE POWER SOURCE CAUTION TO AVOID RISK OF ELECTRIC SHOCK DISCONNECT ALL CABLING FROM THE SYSTEM AND REMOVE THE SYSTEM FROM THE RACK CAUTION TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOLLOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF THE PRODUCT Disconnect from the power source by removing the system from the rack Disconnect all cabling running into ...

Страница 8: ...bient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the a...

Страница 9: ...other resource as a reference pay close attention to the safety instructions Adhere to the assembly instructions in this manual to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components CAUTION ESD CAN DAMAGE DRIVES BOARDS AND OTHER PARTS WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION IF ONE IS NOT AVAILABLE...

Страница 10: ...ards carefully They can be extremely sensitive to electrostatic discharge ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Installing or removing jumpers A jumper is a small ...

Страница 11: ...we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power system because they serve as the product s main power disconnect WARNING The system is safety certified as rack mounted equipment for use in a server room or compute...

Страница 12: ...About the System Chapter 1 This section introduces the system its different configuration s and the main features ...

Страница 13: ... virtualized throughput compared to previous platforms based on the Intel Xeon E5 Processor Family With four 300watt dual width accelerator card while keeping 24 DIMM slots available makes your system support have no limitation to deploy VDI solutions Your system can connect up to 128 concurrent users Eight 3 5 HDD support increases local storage space for rendering application Four U 2 option eli...

Страница 14: ...ery for 85W VRD 13 Number of processors 2 Internal Interconnect 10 4 GT s 9 6 GT s Chipset Intel C621 C624 Memory Total slots 24 Memory type DDR4 2666 MT s RDIMM Memory size 8GB 16GB 32 GB 64 GB 128 GB More options refer to the AVL Storage controller Onboard Intel C621 C624 8 SATA 6Gbps port with 2 mini SAS HD connector 6 sSATA 6Gbps port with 1 mini SAS HD connector reserved and 2 7 pin SATA port...

Страница 15: ...zz 2 GPU x16 from Riser slot 1B or slot 4 CPU1 2 GPU x16 or 2 FHHL x16 from Riser slot 2 or slot 3 1 LP MD 2 PCIe x8 from Riser slot 3 1 LP MD 2 PCIe x8 from Riser slot 2 SKU2 Front Storage Back Expansion Slots SKU2 OPTION3 Front Storage 8 3 5 2 5 SAS SATA Front BP support SAS Mezz QS 3008A QS 3108A and optional supercap Back Expansion Slots CPU0 1 OCP Mezz x16 can switch to PCH if not using OCP m...

Страница 16: ...er ID Status LEDs 2 USB ports 1 VGA port Display Priority First one device one time Back I O 2 USB 3 0 ports 1 VGA port Display Priority Second one device one time 1 RS232 serial port 1 GbE RJ45 management port 1 ID LED 1 MicroSD slot TPM Yes optional SPI mode ACPI ACPI compliance S0 S5 support Power supply 2 1600W 2200W 86mm Platinum redundant PSUs AC HVDC support 1600W Lite on PS 2162 1Q 200 240...

Страница 17: ...nal USB port Operating environment Operating temperature 5 C to 35 C 41 F to 95 F Non operating temperature 40 C to 70 C 40 F to 158 F Operating relative humidity 20 to 85 RH Non operating relative humidity 10 to 95 RH Your system can support SSD only while installing four Tesla V100 cards Table 1 System Specifications Continued SPECIFICATIONS DESCRIPTION ...

Страница 18: ...M PACKAGE CONTENTS 1 6 1 2 Package Contents 1 DS225 system 2 processor heat sinks 2 power supply units optional 2 power cords optional Note For exact shipping contents contact your Hitachi Vantara sales representative ...

Страница 19: ...available as a 3 5 storage drive configuration The 3 5 storage drive configuration system overview is displayed in the following image Figure 1 1 3 5 Storage Drive System Component Overview 8 11 12 10 1 7 4 14 2 5 3 1 6 9 2 3 Fan1 Fan0 Fan2 Fan4 Fan3 Fan5 13 5 15 GPU1 GPU2 GPU4 GPU3 Riser Assembly ...

Страница 20: ...ge Housing up to eight 3 5 HDDs 5 Fan modules x6 Cooling the system 6 CPU socket Install the processor 7 PSU assembly Redundant power supply unit assembly PSU1 8 Riser slot CPU1 Support PCIe add on card and GPU4 installation with riser feature 9 Riser slot CPU1 Support PCIe add on card and GPU3 installation with riser feature 10 OCP slot CPU0 Support OCP 2 0 mezzanine card installation 11 Riser sl...

Страница 21: ... USB port Connect to USB device 4 Front control panel Right Provide VGA and USB connections 5 VGA port Connect to display device Display Priority First one device one time 6 Handle Two server handles used for pulling the system out of the rack CAUTION THE HANDLES ARE DESIGNED FOR THE EXTENSION OF THE SYSTEM FROM THE RACK THE HANDLES ARE NOT DESIGNED TO CARRY THE WEIGHT OF THE SYSTEM DO NOT USE THE...

Страница 22: ...EM SYSTEM FRONT VIEW 1 10 See Enabling the Intel VMD Technology on page 1 15 for more information Table 4 Intel VMD PCIe Root Port BIOS Setup Option Table HDD SLOT CPU SOCKET PSTACK VMD PORT 4 1 0 3C 5 3D 6 2 3A 7 3B ...

Страница 23: ... Panel Definition NO ICON NAME DESCRIPTION 1 Power button with LED Power on off Blue on S0 system power on Off S5 system power off 2 Reset button Soft reset system function 3 System Status LED Provides critical and non critical failure notification Amber blinking failed Off SEL cleared good 4 Identification button with LED Toggles ID LED activate ID LED to identify system Blue blinking Identifier ...

Страница 24: ...e expansion slot with GPU3 or FHFL CPU1 6 PCIe expansion slot with FHHL CPU1 7 PCIe expansion slot with LP MD 2 CPU1 8 PCIe expansion slot with GPU4 or FHFL CPU1 Table 7 System Back I O Definition NO ICON NAME DESCRIPTION 1 Dedicated NIC Dedicated RJ45 connector 2 VGA port Maximum display resolution 1920x1200 32bpp 60Hz reduced blanking Display Priority First one device one time 3 COM A port DB9 p...

Страница 25: ... Model PSU AC INPUT 2 x 1600W and 2200W Platinum high efficiency redundant PSU 2 1600W 2200W 86mm Platinum redundant PSUs AC HVDC support 1600W Lite on PS 2162 1Q 200 240Vac 50 60Hz 10A or 240Vdc 10A 1600W Acbel FSE023 200 240Vac 50 60Hz 10A or 240Vdc 8A 2200W Artesyn MC2200B4 3 4R 02 100 120 200 240Vac 50 60Hz 15 5A 14A Output will be 1200W when input voltage is 100 120Vac Table 9 Power Supply Un...

Страница 26: ...D Blue On System S0 power on Off System S5 power off Identification Blue Blinking Unit selected for identification Off No identification request Status LED Amber Blinking Critical Failure critical fan voltage temperature state Non Critical Failure non critical fan voltage temperature state CPU thermal trip DC off Off SEL cleared Last pending warning or error has been de asserted Table 11 RJ45 LED ...

Страница 27: ...installation but may not be used as the boot volume To enable the Intel VMD technology feature you might need to select Intel VMD technology in IIO configuration under the Socket Configuration screen from BIOS Main screen 10M active link Off Blinking green Table 12 3 5 Storage Drive LED Status Behavior NAME COLOR CONDITION DESCRIPTION Drive Status Fault Blue On Drive is online Blinking Twice per s...

Страница 28: ...ogy is selected Press up or down arrow key to select CPU socket0 or CPU socket1 Then you can enable disable the Intel VMD feature for your system Table 1 1 Intel VMD on Socket X Screen Description SETUP ITEM OPTIONS DESCRIPTION COMMENTS VMD Config for PStack0 Information only Intel VMD for Volume Management Device for PStack0 Disable Enable Enable Disable Intel Volume Management Device Technology ...

Страница 29: ...ure for your system TPM Configuration Settings To setup the TPM configuration you might need to select Trusted Computing in Advanced screen from BIOS Main screen by pressing the right arrow until the Advanced screen is chosen Press the down arrow key until Trusted Computing is selected Intel VMD for Volume Management Device for PStack1 Disable Enable Enable Disable Intel Volume Management Device T...

Страница 30: ...rent available PCR banks SHA 1 PCR Bank Disabled Enabled Enable or Disable SHA 1 PCR Bank Only appears when Available PCR banks includes this type SHA256 PCR Bank Disabled Enabled Enable or Disable SHA256 PCR Bank Only appears when Available PCR banks includes this type Pending operation None TPM Clear Enable Disable Security Device NOTE Your computer will reboot during restart in order to change ...

Страница 31: ......

Отзывы: