K6602705
Rev.3
08.20.01
- 90 -
Table 6.18 Device Configuration Identify Data Structure (continued)
Word
Description
Value (HEX.)
3 - 6
Maximum LBA Address
Words 4 - 7 define the maximum LBA address. This is the
highest address accepted by the device in the factory default
condition. If no DEVICE CONFIGURATION SET command
has been executed modifying the factory default condition,
this is the same value as that returned by a READ NATIVE
MAX ADDRESS command.
DK23DA-40F: 4A8 52FFh
DK23DA-30F: 37E 3E3Fh
DK23DA-20F: 254 297Fh
DK23DA-10F: 12B B22Fh
7
Command Set / Feature Set Supported
bit 15 - 9 0 = Reserved
bit 8
1= 48-bit Addressing feature set supported
bit 7
1 = Host Protected Area feature set supported
bit 6
1 = Automatic acoustic management supported
bit 5
1 = R/W DMA QUEUED commands supported
bit 4
1 = Power-up in Standby feature set supported
bit 3
1 = Security feature set supported
bit 2
1 = SMART error log supported
bit 1
1 = SMART self-test supported
bit 0
1 = SMART feature set supported
008Fh
8 - 254
Reserved
0000h
255
Integrity word
bit 15 - 8 Checksum
The checksum is the two’s complement of the sum of all
byte in words 0 through 254 and the byte consisting of bits
7:0 of word 255. Each byte is added with unsigned
arithmetic, and overflow is ignored. The sum of all bytes is
zero when the checksum is correct.
bit 7 - 0 Signature Code “A5h”
xxA5h