-18-
• Wiring diagram
After completing disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 M
ȍ
or higher (as measured with a 500 VDC megohm tester)
Dielectric strength: 4,000 VAC/1 minute, with no abnormalities --- 220 to 240 V and 110 V for UK products
2,500 VAC/1 minute, with no abnormalities --- 110 to 127 V (Except UK products)
After no-load operation for 30 minutes, the no-load current values should be as follows:
Voltage
110 V
120 V
127 V
220 V
230 V
240 V
Current max.
5.7 A
5.4 A
5.0 A
3.2 A
3.0 A
2.9 A
Connecting diagram
No-load current value
Insulation test
5-wire
8-wire
Panel Ass’y
<67>
On Lock PCB
(A) Ass’y
<92>
Controller Ass’y
<63>
Stator Sensor
PCB Set
<54>
Filter PCB
Ass’y
<71>
On Lock PCB
(B)
[109] {111}
Switch
<77>
3-wire
3-wire
Pillar terminal
Red
Black
Black
Red
Red
White
Black
Black
Red
White