--- 12 ---
[Test conditions]
Posture
: Downward chiseling
Test material
: Concrete panel with a compression strength of 23.5 x 10
6
N/m
2
(240 kgf/cm
2
)
Bull point size
: Bull point of 280 mm
Fig. 4
6-3. Chiseling Performance
Chiseling performance varies considerably depending on the work conditions. Use these factory test results
shown in Fig. 4 as a reference, for comparison purposes only.
DH 42
DH 45SA
DH 40SA
C
160
100
70
70
50
100
150
0
Voltage
230 V
Chiseling quantity (kg/30 min.)
Chiseling quantity in 30 min.