![Hitachi DH 18DBL Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/hitachi/dh-18dbl/dh-18dbl_instruction-manual_145460012.webp)
12
English
Table 2
Indications of the pilot lamp
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for
0.5 seconds. (o
ff
for 0.5 seconds)
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
Charging
impossible Flickers
Lights for 0.1 seconds. Does not light for
0.1 seconds. (o
ff
for 0.1 seconds)
Malfunction in the battery or
the charger
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the Table 3, and batteries that have become
hot should be cooled for a while before being recharged.
Table 3 Recharging ranges of batteries
Rechargeable
battery
Temperatures at which the
battery can be recharged
BSL1850
32°F – 122°F
(0°C – 50°C)
(3) Regarding recharging time (At 68°F (20°C))
Table 4 Charging time (At 20°C)
Charger
Battery
UC18YFSL
BSL1850
Approx. 75 min.
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by
pulling on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the
battery from the battery charger.
NOTE
After operation, pull out batteries from the charger
fi
rst, and then keep the batteries properly.
CAUTION
●
When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes
rest until the next charging.
●
If the battery is charged while it is heated
because it has been left for a long time in a
location subject to direct sunlight or because
the battery has just been used, the pilot lamp of
the charger lights for 1 second, does not light for
0.5 seconds (o
ff
for 0.5 seconds). In such a case,
fi
rst let the battery cool, then start charging.
●
When the pilot lamp
fl
ikers rapidly in red (at
0.2–second intervals), check for and take out
any foreign objects in the charger's battery
connector. If there are no foreign objects,
it is probable that the battery or charger is
malfunctioning. Take it to your authorized
Service Center.
0000DH18DBL̲US.indb 12
0000DH18DBL̲US.indb 12
2016/07/19 10:02:47
2016/07/19 10:02:47