12
Function menu
CU-FUNCTION menu
(*1) In the CAM PWR: OFF case (camera power supply AC230V is not supplied), change in cable mode is
attained. In the case of CAM PWR: ON (camera power supply AC230V is supplied), change in cable mode
becomes improper.
In that case, it becomes impossible to choose the cable mode change item "CABLE
MODE" of a menu screen. (“*” Attach before an item.)
TIME/DATE menu
Item
Setting
Factory setting
Description
BUZZER
ENABLE,
DISABLE
ENABLE
Sets buzzer operation during call input.
ENABLE
: Buzzer sounds.
DISABLE
: Buzzer does not sound.
SDI AUDIO
ON,OFF
OFF
Sets the embedded audio ON/OFF of the
HD-SDI /SD-SDI output.
CABLE MODE HYBRID
SINGLE
HYBRID
Select the mode of optical cable.(*1)
CCU ID
1
~
12
1
Sets the CCU ID.
This ID is required for the SETUP CONTROL
UNIT to identify group of CCU.
SYS FORMAT
Displays the TV format.
TIME/DATE
Moves to the TIME/DATA submenu.
Item
Setting
Factory setting
Description
DATE DISP
OFF, Y.M.D,
M.D.Y, D.M.Y
Y.M.D
Sets the order of date display.
If set OFF, the date is not displayed.
TIME DISP
OFF, ON
ON
Sets the time display.
When ON is selected, the CU-FUNCTION menu
displays the time.
YEAR
00
~
99
-
Sets the year of the date.
MONTH
00
~
12
-
Sets the month of the date.
DAY
00
~
31
-
Sets the day of the date.
HOUR
00
~
23
-
Sets the hours of the time.
MINUTE
00
~
59
-
Sets the minutes of the time.
SET DATA
PUSH
+
-
Press both
and
buttons together to fix
the TIME/DATE setting.
■CU-FUNCTION
BUZZER :ENABLE
SDI AUDIO :OFF
CCU ID : 1
*CABLE MODE: HYBRID
SYS FORMAT 1080i
59.94Hz
TIME/DATE: '09.01.01
12:00
■TIME/DATE
DATE DISP :Y.M.D
TIME DISP :ON
YEAR :09
MONTH :01
DAY :01
HOUR :12
MINUTE :00
SET DATA :PUSH +