14
RS-232C Communication (continued)
RS-232C Communication (continued)
Command Data Chart (continued)
Names
Operation type
Header
Command data
CRC
Action
Type
Setting code
Volume
Get
BE EF
03
06 00
31 D3
02 00
01 20
00 00
Increment
BE EF
03
06 00
57 D3
04 00
01 20
00 00
Decrement
BE EF
03
06 00
86 D2
05 00
01 20
00 00
Mute
Set
TURN OFF
BE EF
03
06 00
46 D3
01 00
02 20
00 00
TURN ON
BE EF
03
06 00
D6 D2
01 00
02 20
01 00
Get
BE EF
03
06 00
75 D3
02 00
02 20
00 00
Lamp Time
Get
BE EF
03
06 00
C2 FF
02 00
90 10
00 00
Lamp Time Reset
Execute
BE EF
03
06 00
58 DC
06 00
30 70
00 00
Filter Time
Get
BE EF
03
06 00
C2 F0
02 00
A0 10
00 00
Filter Time Reset
Execute
BE EF
03
06 00
98 C6
06 00
40 70
00 00
Magnify
Get
BE EF
03
06 00
7C D2
02 00
07 30
00 00
Increment
BE EF
03
06 00
1A D2
04 00
07 30
00 00
Decrement
BE EF
03
06 00
CB D3
05 00
07 30
00 00
Freeze
Set
Normal
BE EF
03
06 00
83 D2
01 00
02 30
00 00
Freeze
BE EF
03
06 00
13 D3
01 00
02 30
01 00
Get
BE EF
03
06 00
B0 D2
02 00
02 30
00 00
Power
Set
TURN OFF
BE EF
03
06 00
2A D3
01 00
00 60
00 00
TURN ON
BE EF
03
06 00
BA D2
01 00
00 60
01 00
Get
BE EF
03
06 00
19 D3
02 00
00 60
00 00
(Example Return)
00 00 01 00 02 00
(Off) (On) (Cool down)
Input Source
Set
M1-D
BE EF
03
06 00
0E D2
01 00
00 20
03 00
RGB
BE EF
03
06 00
FE D2
01 00
00 20
00 00
BNC
BE EF
03
06 00
3E D0
01 00
00 20
04 00
Video
BE EF
03
06 00
6E D3
01 00
00 20
01 00
S-Video
BE EF
03
06 00
9E D3
01 00
00 20
02 00
Component
BE EF
03
06 00
AE D1
01 00
00 20
05 00
Get
BE EF
03
06 00
CD D2
02 00
00 20
00 00
Error Status
Get
BE EF
03
06 00
D9 D8
02 00
20 60
00 00
(Example of Return)
00 00 01 00 02 00 03 00
(Normal) (Cover-error) (Fan-error) (Lamp-error)
04 00 05 00 06 00 07 00 08 00
(Temp-error) (Air flow- (Lamp- (Cool-error) (Filter-Error)
error) Time-over)
(This table is continued to the following page.)