37
CP-A100 / ED-A100 / ED-A110 (A1DN)
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Lighting
In Orange
Turned
off
Turned
off
The projector is in a standby state.
Blinking
In Green
Turned
off
Turned
off
The projector is warming up.
Please wait.
Lighting
In Green
Turned
off
Turned
off
The projector is in an on state.
Ordinary operations may be performed.
Blinking
In Orange
Turned
off
Turned
off
The projector is cooling down.
Please wait.
Blinking
In Red
(discre-
tionary)
(discre-
tionary)
The projector is cooling down. A certain error has been detected.
Please wait until the POWER indicator finishes blinking, and then perform the proper
measure using the item descriptions below.
Blinking
In Red
or
Lighting
In Red
Lighting
In Red
Turned
off
The lamp does not light, and there is a possibility that interior portion has become
heated.
Please turn the power off, and allow the projector to cool down at least 20 minutes.After
the projector has suf
fi
ciently cooled down, please make con
fi
rmation of the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air
fi
lter dirty?
• Does the peripheral temperature exceed 35ºC?
If the same indication is displayed after the remedy, please change the lamp referring to
the section “Lamp”.
Blinking
In Red
or
Lighting
In Red
Blinking
In Red
Turned
off
The lamp cover has not been properly
fi
xed (attached).
Please turn the power off, and allow the unit to cool down at least 45 minutes. After the
projector has suf
fi
ciently cooled down, please make con
fi
rmation of the attachment state of
the lamp cover. After performing any needed maintenance, turn the power on again.
Lighting
In Red
Turned
off
Turned
off
The lens door is not opened or closed properly.
One of the followings has been happened.
• The lens door is not opened properly, when the projector is turned on.
• The lens door is not closed properly, when the projector is turned off.
• The lens door position is shifted, while the projector is working.
Restart the projector, after confirming that there is nothing that the lens door hits while
opening or closing.
Blinking
In Red
or
Lighting
In Red
Turned
off
Blinking
In Red
The cooling fan is not operating.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suf
fi
ciently cooled down, please make con
fi
rmation that no foreign matter has
become caught in the fan, etc., and then turn the power on again.
If the same indication is displayed after the remedy, please replace a fan.
Blinking
In Red
or
Lighting
In Red
Turned
off
Lighting
In Red
There is a possibility that the interior portion has become heated.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has sufficiently cooled down, please make confirmation of the following items,
and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air
fi
lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy, please set the FAN SPEED of the
SERVICE item in the OPTION menu to HIGH.
Lighting
In Green
Alternative
blinking in Red
There is a possibility that the interior portion has become overcooled.
Please use the unit within the usage temperature parameters (5°C to 35°C). After the
treatment, resent the power to ON. If the same indication is displayed after the treatment,
please make sure that the proper cables are connected to each of connectors E301, E302
and E304 on the PWB assembly MAIN.
Lighting
In Green
Simultaneous
blinking in Red
It is time to clean the air
fi
lter.
Please immediately turn the power OFF, and clean or change the air
fi
lter referring to the
section “Air Filter”. After cleaning or change the air
fi
lter, please be sure to reset the
fi
lter
timer. After the remedy, resent the power to ON.
Blinking
in Green
for approx.
3 seconds
Turned
off
Turned
off
At least 1 "Power ON" schedule is saved to the projector.
(
Please refer to the User's Manual Network Functions: Schedule Setting for more
information)
NOTE
• When the interior portion has become overheated, for safety purposes, the power source is automati-
cally turned off, and the indicator lamps may also be turned off. In such a case, press the “
○
” (OFF) side of the
power switch, and wait at least 45 minutes. After the projector has suf
fi
ciently cooled down, please make con-
fi
rmation of the attachment state of the lamp and lamp cover, and then turn the power on again.
6-14 Regarding the indicator lamps
Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings
as described in the table below. Please respond in accordance with the instructions within the table.
Содержание CP-A100 Series
Страница 14: ...14 CP A100 ED A100 ED A110 A1DN 5 Troubleshooting Check points ...
Страница 92: ...92 CP A100 ED A100 ED A110 A1DN MEMO ...
Страница 93: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 CONFIDENTIAL ...
Страница 94: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 CONFIDENTIAL ...
Страница 95: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 1 CONFIDENTIAL ...
Страница 96: ...CP A100 ED A100 ED A110 A1DN 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 2 CONFIDENTIAL ...
Страница 114: ...QR73841 Printed in Japan JE CP A100 ED A100 ED A110 YK No 0599E ...