![Hitachi AMS 2000 Series Скачать руководство пользователя страница 165](http://html.mh-extra.com/html/hitachi/ams-2000-series/ams-2000-series_reference-manual_146092165.webp)
Maintenance log and tracing functions
3–9
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
Sense code and detail code
shows sense codes and detailed codes. 0~A will be set in the x of
detailed codes.
•
Table 3-5: Sense Codes
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
2602
The primary sequence number is
beyond the limits of supported.
Check the serial number.
2602
The secondary sequence number
is beyond the limits of supported.
Check the serial number.
2602
The LUN of the P-VOL is beyond
the limits of supported.
Check the specified LUN.
2602
The LUN of the S-VOL is beyond
the limits of supported.
Check the specified LUN.
2602
The primary port number is
beyond the limits of supported.
Check the specified port
number.
2602
The secondary port number is
beyond the limits of supported.
Check the specified port
number.
2602
The object LU is beyond the limits
of supported.
Check the status of the LU.
2602
The object LU is undefined.
Check the status of the LU.
2602
The environment has a problem.
Check the environment of
CCI.
2602
The retention term is beyond the
limits of validity.
Check that the specified
value that has been set is 0 to
21900.
3180
The object LU is unformatted.
Check the status of the LU.
9501
A command was received during
execution of the pseudo deliberate
shutdown.
Retry after the pseudo
deliberate shutdown is
completed.
9510
A command was received during a
performance of hot replacement of
the firmware.
Retry after waiting for a
while.
9531
The password protection is being
logged in.
Retry after waiting for a
while.
9536
The optional feature is invalid.
Install the optional feature.
9552
The object LU is defined as a
command device.
Check the attribute of the LU.
9557
LU capacities of the P-VOL and S-
VOL are not the same.
Check the capacity of the LU.
956B
The capacity is beyond the limits
of supported.
Split the unnecessary pairs.
9576
0000
84
The pair status of the P-VOL is
other than SMPL.
Check the pair status of the
LU.
9576
0001
84
The status of the P-VOL is other
than normal or regressive.
Check the status of the LU.
9576
0002
84
The P-VOL is a Cache Residency
LU.
Check the status of the LU.
Содержание AMS 2000 Series
Страница 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 226: ...3 70 Maintenance log and tracing functions Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...