2
DW1U
NOTICE:
Comply with all cautions and safety-related notes
located on or inside the cover case and on the chassis or plasma
module.
WARNING:
Since the chassis of this receiver is connected to
one side of the AC power supply during operation, whenever the
receiver is plugged in service should not be attempted by any-
one unfamiliar with the precautions necessary when working on
this type of receiver.
1. When service is required, an isolation transformer should be
inserted between power line and the receiver before any
service is performed on a “HOT” chassis receiver.
2. When replacing a chassis in the receiver, all the protective
devices must be put back in place, such as barriers, non-
metallic knobs, insulating cover-shields, and isolation
resistors, capacitors, etc.
3. When service is required, observe the original lead dress.
4. Always use manufacturer’s replacement components. Critical
components as indicated on the circuit diagram should not be
replaced by another manufacturer’s. Furthermore, where a
short circuit has occurred, replace those components that
indicate evidence of over heating.
5. Before returning a serviced receiver to the customer, the
service technician must thoroughly test the unit to be certain
that it is completely safe to operate without danger of electrical
shock, and be sure that no protective device built into the
receiver by the manufacturer has become defective, or
inadvertently defeated during servicing.
Therefore, the following checks should be performed for the
continued protection of the customer and service technician.
Leakage Current Cold Check
With the AC plug removed from the 120V AC 60Hz source,
place a jumper across Line 1 and Line 2 of the three plug
prongs, do not connect with the third prong, which is physical
ground.
Using an insulation tester (DC500V), connect one of its leads
to the AC plug jumper and touch with the other lead each
exposed metal part (antennas, screwheads, metal overlays,
control shafts, etc.), particularly any exposed metal part
having a return path to the chassis should have a resistor
reading over 4M
Ω
. Any resistance value below this range
indicates an abnormality which requires corrective action. An
exposed metal part not having a return path to the chassis will
indicate an open circuit.
SAFETY PRECAUTIONS
Leakage Current Hot Check
AC LEAKAGE TEST
ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED
ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD
AND MUST BE CORRECTED BEFORE RETURNING THE
RECEIVER TO THE CUSTOMER.
LEAKAGE
CURRENT
TESTER
(READING
SHOULD NOT
BE ABOVE 0.5MIU)
EARTH
GROUND
TEST ALL
EXPOSED
METAL SURFACES
DEVICE
UNDER
TEST
3-WIRE CORD
ALSO TEST WITH PLUG
REVERSED
(USING AC ADAPTER
PLUS AS REQUIRED)
TABLE OF CONTENTS
Plug
the AC line cord directly into a 120V AC outlet. (Do not use an
isolation transformer during this test.) Use a leakage current
tester or a metering system that complies with the American
National Standards Institute (ANSI) C101.0 Leakage Current
for Appliances. In the case of the PDP monitor set the AC
switch first in the ON position and then in the OFF position,
measure from across Line 1 and Line 2 of the three plug
prongs, do not connect with the third prong, which is physical
ground, to all exposed metal parts of the instrument
(antennas, handle bracket, metal cabinet, screw heads,
metallic overlays, control shafts, etc.), especially any exposed
metal parts that offer an electrical return path to the chassis.
Any current measured must not exceed 0.5 MIU. Reverse the
instrument power cord plug in the outlet and repeat test.
AC Inlet Polarity
This check is based on the UL Standard
Use the jigs specified by the production technology section.
The GND side (Wider blade) of the AC power cord should
be connected to F902.
GI
Содержание 55HDS52/DW1-U
Страница 79: ...CONNECTION DIAGRAM DW1U TABLE OF CONTENTS 78 55 Models Only ...
Страница 80: ...DW1U 79 FINAL WIRING DIAGRAM TABLE OF CONTENTS GI ...
Страница 88: ...FINAL ASSEMBLY GUIDE 87 TABLE OF CONTENTS GI ...
Страница 89: ...FINAL ASSEMBLY GUIDE 88 TABLE OF CONTENTS GI ...
Страница 90: ...FINAL ASSEMBLY GUIDE 89 TABLE OF CONTENTS GI ...
Страница 91: ...FINAL ASSEMBLY GUIDE 90 TABLE OF CONTENTS GI ...
Страница 92: ...FINAL ASSEMBLY GUIDE 91 TABLE OF CONTENTS GI ...
Страница 93: ...FINAL ASSEMBLY GUIDE 92 TABLE OF CONTENTS GI ...
Страница 94: ...FINAL ASSEMBLY GUIDE 93 TABLE OF CONTENTS GI ...
Страница 121: ...PRINTED CIRCUIT BOARDS DW1 U 55 TERMINAL PWB Solder side DW1 U PRINTED CIRCUIT BOARDS DW1 U TABLE OF CONTENTS 120 ...
Страница 124: ...PRINTED CIRCUIT BOARDS DW1 U CONTROLPWB DW1 U Component side INM1 IC Component side Solder side TABLE OF CONTENTS 123 ...
Страница 125: ...PRINTED CIRCUIT BOARDS DW1 U FILTER PWB DW1 U Component side Solder side TABLE OF CONTENTS 124 ...
Страница 126: ...PRINTED CIRCUIT BOARDS DW1 U SWITCH PWB DW1 U Component side Solder side TABLE OF CONTENTS 125 ...
Страница 127: ...PRINTED CIRCUIT BOARDS DW1 U SWITCH PWB DW1 U Component side Solder side INS1 IC Component side TABLE OF CONTENTS 126 ...
Страница 140: ......