Error code table (H1 panel)
Suspected faulty board
(In the order of higher probability of defect)
ERR
Code
Detect
position
(board)
Contents
(1) (2) (3) (4) (5) (6) (7)
Remarks
04
LOGIC
3.3V power voltage has dropped
LOGIC
PSU
06
3.3V power startup is faulty
X-SUS
Y-SUS
ADM1 - 8 PSU
ABUS-L ABUS-R LOGIC
18
Internal I2C_SCL1_LOW level
LOGIC
19
Internal I2C_ACK does not respond
LOGIC
1C
EEPROM initial setting is defective
LOGIC
1D
EEPROM write-down is defective
LOGIC
1E
EEPROM user initial setting is defective
LOGIC
1F
EEPROM factory setting reading is defective
LOGIC
24
X-SUS
Vex power voltage has decreased
X-SUS
LOGIC
25
Vex power voltage is excessive
X-SUS
26
Vex power startup is faulty.
X-SUS
LOGIC
28
Vx power voltage has dropped
X-SUS
LOGIC
29
Vx power voltage is excessive
X-SUS
2A
Vx power startup is faulty.
X-SUS
LOGIC
2C
Vpx voltage has dropped
X-SUS
LOGIC
2D
Vpx voltage is excessive
X-SUS
LOGIC
30
Vpx1 voltage has dropped
X-SUS
LOGIC
31
Vpx1 voltage is excessive
X-SUS
LOGIC
34
Vpx2 voltage has dropped
X-SUS
LOGIC
35
Vpx2 voltage is excessive
X-SUS
LOGIC
39
Vs power current is excessive (during operation)
X-SUS
Panel
LOGIC
3B
Vs power current is excessive (during startup)
X-SUS
Panel
LOGIC
44
Y-SUS
Vey power voltage has dropped
Y-SUS
LOGIC
45
Vey power voltage is excessive
Y-SUS
46
Vey power startup is faulty.
Y-SUS
LOGIC
4C
Vpy voltage has dropped
Y-SUS
LOGIC
4D
Vpy voltage is excessive
Y-SUS
LOGIC
50
Vpy1 voltage has dropped
Y-SUS
LOGIC
51
Vpy1 voltage is excessive
Y-SUS
LOGIC
54
Vpy2 voltage has dropped
Y-SUS
LOGIC
55
Vpy2 voltage is excessive
Y-SUS
LOGIC
59
Vs power current is excessive (during operation)
Y-SUS
Panel
LOGIC
5B
Vs power current is excessive (during startup)
Y-SUS
Panel
LOGIC
5D
Vs power current is excessive (during operation)
Y-SUS
SDM
Panel
LOGIC
61
PSU
Vs power voltage is excessive
PSU
LOGIC
62
Vs power startup is faulty.
X-SUS
Y-SUS
PSU
LOGIC
64
Vex and Vpy power voltage has dropped
LOGIC
X-SUS
Y-SUS
65
Vex and Vey power voltage is excessive
X-SUS
Y-SUS
66
X-SUS
Y-SUS
Vex and Vey power startup is faulty.
LOGIC
X-SUS
Y-SUS
68
X-SUS
Vw power voltage has dropped
Y-SUS
X-SUS
LOGIC
69
Vw power voltage is excessive
X-SUS
6A
Vw power startup is faulty.
Y-SUS
X-SUS
LOGIC
6C
Vpx and Vpy voltage has dropped
LOGIC
X-SUS
Y-SUS
6D
X-SUS
Y-SUS
Vpx and Vpy voltage is excessive
LOGIC
X-SUS
Y-SUS
10
Содержание 42PMA400E
Страница 24: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...
Страница 25: ...HITACHI SM0064 Power Supply Block Diagram ...
Страница 26: ...HITACHI SM0064 Panel Connectors ...
Страница 28: ...HITACHI SM0064 Power Supply Circuit Board ...
Страница 29: ...HITACHI SM0064 Power Circuit Schematic 1 of 5 ...
Страница 30: ...HITACHI SM0064 Power Circuit Schematic 2 of 5 ...
Страница 31: ...HITACHI SM0064 Power Circuit Schematic 3 0f 5 ...
Страница 32: ...HITACHI SM0064 Power Circuit Schematic 4 of 5 ...
Страница 33: ...HITACHI SM0064 Power Circuit Schematic 5 of 5 ...