background image

4

STAPLE SELECTION

Choose a suitable staple from Fig. Staples which are not
shown in Fig. can not be driven with this tool.

2. Check on safety
CAUTIONS:

Unauthorized persons (including children) must be
kept away from the equipment.

Wear eye protection.

Check the retaining screws which fix the exhaust
cover, etc. for tightness.
Check the stapler for air leaks and defective or rusty
parts.

Check whether or not the push lever works correctly.
Also check whether or not any dirt has adhered to the
moving parts of the push lever.

Recheck on operational safety.

BEFORE USE

1. Check the air pressure
CAUTION:

The air pressure must be constantly maintained at 4.9
– 8.3 bar (70 – 120 psi.).
Adjust the air pressure between 4.9 to 8.3 bar (70 –
120 psi.) according to the diameters and length of
staples and hardness of the wood being stapled. Pay
special attention to the output pressure, capacity, and
piping on the air compressor, so that air pressure does
not exceed the specified limit. Note that excessive
pressure may affect overall performance, service life,
and safety.

2. Lubrication

(1) Prior to operating this stapler, be sure to provide an

air set between the air compressor and this device.
Lubrication through the air set offers smooth
operation, extended service life, and anticorrosion.
Adjust the oiler so that a single drop of oil is supplied
at intervals of 5 to 10 stapling cycles.

(2) It is recommended using the recommended oil (SHELL

TONNA). Other applicable oils are listed. Never mix
two or more types of different oils.

3. Load staples
CAUTIONS:

When loading staples into stapler,
(1) do not depress trigger;
(2) do not depress push lever; and
(3) keep your face, hands feet and other body parts,

as well as those of other persons away from the
nose muzzle to avoid possible injury during usage
and carrying.

(1) Pull the staple feeder backward and attach it securely

to a groove of the magazine.  (See 

Fig. 2

)

Fig. 2

16 Gauge    7/16" Crown

Min.

Max.

1.45mm
(.057")

7.9mm
(.309")

1.61mm

(.063")

25mm (1")

50mm (2")

Dimension of staples

STANDARD ACCESSORIES

(1) Hexagon bar wrench for M5 screw ........................... 1
(2) Eye protection ............................................................. 1

OPTIONAL ACCESSORY

Sequential Trip Mechanism Kit (Code No.876762)
(Sequential Fire Parts Set, Single Shot Parts)
With the sequential fire parts, the staple is driven
only by squeezing the trigger after pushing down
the push lever.
By installing these parts, driving staples into
improper positions and unexpected firing of staples
caused by accidental operation of the push lever can
be prevented.

APPLICATIONS

Construction work such as wall sheathing,
subflooring.

Mobile and modular home construction.

PREPARATION PRIOR TO OPERATION

1. Prepare the hose

Be sure to use the hose provided with minimum
6 mm (1/4”) inside diameter.

NOTE:

The air supply hoses must have a minimum working
pressure rating of 12.8 bar (180 psi) or 150 percent of
the maximum pressure produced in the air supply
system, whichever is higher.

Groove

Staple Feeder

01Eng_N5008AC2_Eng

08/7/31, 22:46

4

Содержание N 5008AC2

Страница 1: ...8AC2 Stapler Read through carefully and understand these instructions before use Keep this Manual available for others before they use the Stapler Handling instructions 001Cover_N5008AC2_Eng 08 7 31 22 45 1 ...

Страница 2: ...d only for authorized service center PRECAUTIONS ON USING STAPLER 1 Safe operation through correct usage This tool was designed for driving staples into wood and similar materials Use it for its intended purpose only 2 Make sure air pressure is within the rated range of air pressure Fastener driving tools operated by compressed air shall only be connected to compressed air lines where the maximum ...

Страница 3: ...aple currently being driven in comes into contact with a previous staple or a knot in the wood 17 Take care when stapling thin boards or the corners of wood When stapling thin boards the staples may pass right through as may also be the case when stapling the corners of wood due to deviation of the staples In such cases always make sure that there is no one and nobody s hands or feet etc behind th...

Страница 4: ...5 mm L 258 mm H 76 mm W 14 3 8 10 5 32 3 Weight 2 0 kg 4 4 lbs Hose inside diam 6 mm 1 4 SPECIFICATIONS Piston Piston O Ring Driver Blade Nose Lock Lever Blade Guide Push Lever Firing Head outlet Push Lever Piece Staple Feeder Magazine Assembly Magazine Cover Air Plug Cap Body Trigger Exhaust Cover Fig 1 NAME OF PARTS 01Eng_N5008AC2_Eng 08 7 31 22 46 3 ...

Страница 5: ...ng cycles 2 It is recommended using the recommended oil SHELL TONNA Other applicable oils are listed Never mix two or more types of different oils 3 Load staples CAUTIONS 䡬 When loading staples into stapler 1 do not depress trigger 2 do not depress push lever and 3 keep your face hands feet and other body parts as well as those of other persons away from the nose muzzle to avoid possible injury du...

Страница 6: ...t several staples instead of just one in rapid succession when strongly pressed flush against a surface or when using on hard materials In such cases fire the staples by squeezing and quickly releasing the trigger 2 Push lever When depressing the staple outlet be sure to fully lift the push lever See Fig 5 to release the safety lock Thus staples cannot be driven without releasing the safety lock e...

Страница 7: ... to a suitable depth If an overly high pressure is used the life of the piston damper etc will be shortened INSPECTION AND MAINTENANCE CAUTION Be sure to disconnect the hose during cleaning jams inspection maintenance and cleaning 1 Countermeasure for staple jamming 1 Remove all staples 2 Release the lock lever and open the blade guide See Fig 8 Fig 8 3 Remove the jammed staple with a slotted head...

Страница 8: ...egulations and standards prescribed in each country must be observed MODIFICATIONS Hitachi Power Tools are constantly being improved and modified to incorporate the latest technological advancements Accordingly some parts may be changed without prior notice COMPRESSOR CAUTION When the maximum operating pressure of the air compressor exceeds 8 3 bar 120 psi be sure to provide a reducing valve betwe...

Страница 9: ...8 02Back_N5008AC2_Eng 08 7 31 22 46 8 ...

Страница 10: ...9 02Back_N5008AC2_Eng 08 7 31 22 46 9 ...

Страница 11: ... 1 37 HEX SOCKET HD BOLT M5 16 3 38 AIR PLUG NPT 1 4 1 39 VALVE GUARD 1 40 ROLL PIN D3 45 1 41 HITACHI PLATE 1 42 NYLOCK BOLT W FLANGE M5 8 2 43 GUARD 1 44 HANDLE ARM 1 45 WARNING LABEL 1 46 MAGAZINE COVER 1 47 WASHER 1 48 HEX SOCKET HD BOLT M5 18 1 49 PLUNGER SPRING 1 50 PLUNGER A 1 51 PLUNGER O RING 1 52 O RING S 12 3 53 VALVE BUSHING 1 54 PLUNGER B 1 55 VALVE PACKING 1 56 URETHANE BALL C D7 14 ...

Страница 12: ...Hitachi Koki Co Ltd 809 Code No C99173911 Printed in Taiwan 02Back_N5008AC2_Eng 08 7 31 22 46 11 ...

Отзывы:

Похожие инструкции для N 5008AC2