Hit-Not DDAC-PDS-SYS-2 Скачать руководство пользователя страница 2

St

ep

 10

www.hitnot.com

All adjustments in Steps 7-9 need to be done by a professional.

03/15/2022

DDAC20040rev3.8

St

ep

 12

* To ensure proper functionality under all conditions  the Danger Zone limit 

should not exceed 30’ with DDAC PADs and 39’ with Type A PADs.  If a larger 

field is required, contact Frederick Mobile Instrumentation  for options. 

The clear plastic cover on the Warning Module 
can be turned to reduce the sound.

If the sound still needs to be reduced, remove 
the bottom cover of the generator with a Phillips 
head screwdriver.

Turn on the truck and activate the PAD.

Adjust the “VOL” pot with a 3/32” slotted 

screwdriver.  Slowly turn the VOL pot 
counterclockwise to decrease and clockwise to 
increase the volume. 

Do NOT turn beyond the 

“STOP”. 

Return the bottom cover if Volume is correct.

Ensure all other MFGs and PADs within 90 ft 
are off. Power on 1 PAD at the distance the 
field should be set to and leave it there. 
Remove the Clear Pull Tab and Power on the 
range adjust tool within 4ft of MFG.  The 
warning module will sound.  Hold down 
both switches for 5 seconds. Release. Press 
the Red switch to increase the range and the 
Black switch to decrease the range.  The 
maximum danger range using a DDAC PAD is 

30’ and for a Type A PAD it is 39’.

The field is factory set to 30’ Danger Zone. 

St

ep

 9

St

ep

 11

Range Adjust 

using Range Adjust Tool 

Range Adjust 

using Potentiometers

Volume Adjust 

using Potentiometers

For Units in Weather shields see Step 9 to adjust Range

For Units in Weather shields see Step 8 to adjust Range

St

ep

 13

Alerting Signals

Factory Field Size 
@ 12-15V

:

Warning: 43ft
Danger: 30ft
Tolerance: ±1ft

PAD (Pedestrian Alert)

Warning Zone-
Series of 3 beeps

Danger Zone-
Continuous signal

To check the field,  
hold a PAD at the 
edge of the 
Danger zone on 
the long axis of 
the Generator. 
Slowly move the 
PAD from Danger 
to Warning.

LOW BATTERY ON PAD:  
Series of 2 beeps. PAD will 
not indicate Alert Signals!

CAM Alert (Truck to Truck) (If Equipped)

Generator will beep rapidly for 2 seconds 
when it receives the CAM signal from the 
other truck.  The signal will reset when a 
PAD comes in the Warning Zone.

To check the field for a Truck 
with CAM, bring another 
Truck with CAM facing each 
other outside the Warning 
Zone. Slowly move a Truck 
into the Warning zone.  
Rapids beeps will sound on 
both trucks. The standard 
alarm times out after 5 
seconds.

NOTE: A Generator/Truck without a CAM can be used with a CAM Truck 
to check the field.  The NO CAM Truck will receive the warning of the CAM 
Truck.  The CAM Truck will not activate an alarm on 

it’s

own truck.

Functionality of Switches

SW 2

SW 2
SW 1

SW 1

Switch 1 

In the on position 

(switch towards 

point of arrow

) the sound maintains its 

setting under all conditions. In the off 
position the sound is maximum when 
entering a zone for the first 3 seconds then 
the sound level returns to its setting. 

Switch 2 

in the on position disables 

Collision Avoidance [only applicable if CAM 
installed on unit]

Check the Direction of the Arrow 

on Switch for Correct Orientation

(       UP = ON)

Remove bottom cover-see step 10

Have a Pedestrian with a PAD at the 
desired Danger Zone Limit * Adjust the 

“PWM” pot with a 3/32” slotted 

screwdriver.  Slowly turn the PWM pot 
(counterclockwise to decrease and 
clockwise to increase the Zones) until the 
danger zone alerts at the desired distance. 

Do NOT turn beyond the “STOP”. 

Return bottom cover.

Volume

PWM

These Switches are for Gen-2 Systems

Step

 1

4

Fault Code Identification

1. Warning Module

The Warning Module will beep at a Rate of 2 Beeps every 5 Seconds. This 

Alert Pattern is Notably Different than any other Alerts (Warning, Danger, 
Collison Avoidance).

2. Yellow LED on Magnetic Field Generator (MFG)

To Identify the Fault, you must be able view the Yellow LED that is Located on the 
Magnetic Field Generator (MFG) beside the Blue (Power) LED.
I.

If the Yellow LED is NOT Blinking the Fault is; The MFG is NOT 

Communicating with the Collision Avoidance Module. 

a)

Return to Factory using RMA

II.

If the Yellow LED is Blinking ONCE the Fault is; The Pre-Set Magnetic Field is 

NOT able to reach the Desired (TARGET) Setting.

Check the Following;
a)

Mounting, Review Step #1, NOTE: MFG CANNOT be 
Completely Enclosed in 360° of Metal.

b) Re-Set the Magnetic Field Distance, Review Steps 9 & 11.
c)

Return to Factory using RMA

III. If the Yellow LED is Blinking Twice the Fault is; LOW Input Voltage

Check the Following;
a)

For DDAC you MUST Maintain 12 VDC to System.

b) For SXL you MUST Maintain 24 VDC to System.

DDAC MFG System Installation Guide

Model #; DDAC-PDS-SYS-2