Under normal operating conditions, the batteries will last a minimum of 
one year.  
 

Note: Constant exposure to high or low humidity may reduce 
battery efficiency. 
 

Unit Malfunction 

Your CO alarm performs an internal self-diagnosis every minute to make 
sure that it is functioning properly. In the rare event that your alarm 
malfunctions, the apparatus will sound a double short chirp and the 
yellow LED flash simultaneously in every minute. In this case the alarm 
must be replaced. 

 
Never ignore a CO unit’s alarm. A true alarm is an indication of potentially 
dangerous levels of carbon monoxide. CO alarms are designed to alert 
you to the presence of carbon monoxide before an emergency, before 
most people would experience symptoms of carbon monoxide poisoning, 
giving you time to resolve the problem calmly.  
 
 

TESTING YOUR CO ALARM 

It is recommended that you test your CO alarm once a month to ensure 
the alarm is working correctly. 

 
Test the unit by depressing the Test/Reset button. The red LED will flash 
and the buzzer will chirp 6 times simultaneously.  Then the unit will enter 
into the normal operation mode and the green light should flash once a 
minute. 

 
 

WHAT TO DO IF THE ALARM SOUNDS 

 
        WARNING

 

Actuation of your CO alarm indicates the presence of carbon 
Monoxide (CO), which can KILL YOU.
 
If alarm signal sounds: 
1.

 

Immediately move to fresh air – outdoors or by an open 
door/window. Do a head count to check that all persons are 
accounted for. 

2.

 

Where possible turn off all fuelled appliances and stop using them.  

3.

 

Call your emergency services  

4.

 

Do not re-enter the premises nor move away from the open 
door/window until emergency services responders have arrived, the 
premises have been aired out, and your alarm remains in its normal 
condition. 

5.

 

Call a qualified appliance technician to investigate for sources of 

CO from fuel burning equipment and appliances, and inspect for 
proper operation of this equipment. If problems are identified during 
this inspection have the equipment serviced immediately. Note any 
combustion equipment not inspected by the technician and consult 
the manufacturers’ instructions, or contact the manufacturers 
directly, for more information about CO safety and this equipment. 
Make sure that motor vehicles are not, and have not been, 
operating in an attached garage or adjacent to the residence. 

 
 

MAINTAINING YOUR CO ALARM 

Your alarm will alert you to potentially hazardous CO concentrations in 
your home when maintained properly. To maintain your alarm in proper 
working order, it is recommended that you: 

 

Test your alarm at least once a month. 

 

Clean the outside case regularly to prevent dust or dirt build up in 

the slots. DO NOT USE CLEANING AGENTS, BLEACH, POLISH 
OR ANY CHEMICALS. Chemicals can permanently damage or 
temporarily contaminate the sensor. Simply wipe with a damp 
cloth OR a clean tissue.  

 

Do not paint the CO alarm 

 
NOTE - If you will be staining or stripping wood floors or furniture, 
painting, wall-papering, or using aerosols or adhesives, remove 
the CO alarm to a remote location before in order to prevent 

possible damage to or contamination of the sensor. 
 
The following is a list of substances which, at high levels, can 
affect the sensor and may cause a nuisance alarm that is not a 
carbon monoxide alarm. 
 
Methane, propane, iso-butane, ethylene, ethanol, alcohol, iso-
propanol, benzene, toluene, ethyl acetate, hydrogen, hydrogen 
sulfide, sulfur dioxides. 
 
Also most aerosol sprays, alcohol based products, paints, 
solvents, adhesives, hair sprays, after shaves, perfumes and some 
cleaning agents. 
 
 

BATTERY REPLACEMENT

 

If the CO Alarm emits a short ‘beep’ once a minute the battery is at 
the end of its life and should be replaced immediately. This low 
voltage warning will be given for at least 30 days. 

 

Remove the battery from the compartment.  

 

Insert a new, healthy 9V battery. NOTE POLARITY OF 

CONNECTIONS.  

 

Using the Push-to-Test button to test the CO Alarm. See 

“TESTING YOUR CO ALARM” 

 

Reattach the CO alarm to the mounting plate.  

 
WARNING: DANGER OF EXPLOSION IF BATTERY IS 
INCORRECTLY REPLACED.  THE USE OF BATTERIES OTHER 
THAN THOSE RECOMMENDED ON THE BACK OF THE CO 
ALARM MAY BE DETRIMENTAL TO ITS OPERATION 
 
 

SYMPTOMS OF CO POISONING

 

The following symptoms may be related to CO poisoning: 
35 ppm 

The maximum allowable concentration for  
continuous exposure for healthy adults in any  
8 hour period. 

200 ppm 

Slight headaches, fatigue, dizziness, nausea  
after 2-3 hours 

400 ppm 

Frontal headaches within 1-2 hours, life  
threatening after 3 hours. 

800 ppm 

Dizziness, nausea and convulsions within 45  
minutes. Unconsciousness within 2 hours. Death 
within 3 hours. 

1600 ppm 

Headache, dizziness and nausea within 20  

minutes. Death within 1 hour 

6400 ppm 

Headache, dizziness and nausea within 1-2  
minutes 

 
The following symptoms re related to CARBON MONOXIDE 
POISONING and are to be discussed with ALL members of the 
household: 
 
Mild Exposure: Slight headache, nausea, vomiting, fatigue (often 
described as “flu-like” symptoms). 
Medium Exposure: Severe throbbing headache, drowsiness, 
confusion, fast heart rate. 
Extreme Exposure: Unconsciousness, convulsions, cardio-
respiratory failure, death. 
 
Many cases of reported CARBON MONOXIDE POISONING 

indicate that while victims are aware they are not well. They 

become so disoriented they are unable to save themselves by 
either the building or calling for assistance. Young children and 
household pets are typically the first affected. 

 
The apparatus may not prevent the chronic effects of carbon 
dioxide exposure and that the apparatus will not fully 
safeguard individuals at special risk.  
 

 
IMPORTANT SAFEGUARDS 

Installation of your CO alarm is only one step in your safety plan. 
Educate yourself and family to the sources and symptoms of CO 
poisoning and how to use your carbon monoxide alarm:- 

 

Replace the battery immediately once depleted 

 

Buy appliances accepted by a recognized testing 

laboratory. 

 

Install the appliances properly, following the manufacturers’ 

instructions. 

 

Have installations done by professionals. 

 

Have your appliances checked regularly by a qualified 

serviceman. 

 

Clean chimneys and flues yearly. 

 

Make regular visual inspections of all-fuel-burning 

appliances. 

 

Check appliances for excessive rust and scaling. 

 

Do not barbecue indoors, or in attached garage. 

 

Open windows when a fireplace or wood burning stove is 

in use. 

 

Be aware of CO poisoning symptoms. 

 

DO NOT: 

 

Burn charcoal inside your home, RV, camper, tent or cabin 

 

Install, convert or service fuel burning appliances without 

proper knowledge, skill and expertise 

 

Use a gas range, oven or clothes dryer for heating 

 

Operate unvented gas burning appliances using kerosene 

or natural gas in closed room 

 

Operate gasoline powered engines indoors or in confined 

areas 

 

Ignore a safety device when it shuts an appliance off 

 

Ignore any warning from your CO alarm 

 

 
END OF UNIT LIFE 

 

The apparatus will operate up to 3 years under normal use. A 
fresh battery should last for at least one year. The apparatus must 
be replaced when a fault warning signal is given.  

 

NOTE: With normal use the battery will last at least 1 year. 
However, battery life will be reduced if either a fault occurs 
with the battery or the apparatus remains in alarm for long 
periods of time.  

 

 
THIS PRODUCT CANNOT BE REPAIRED – IF THE UNIT IS 
TAMPERED WITH IT WILL INVALIDATE THE GUARANTEE. IF 
THE UNIT IS FAULTY PLEASE RETURN IT TO YOUR 
ORIGINAL SUPPLIER WITH YOUR PROOF OF PURCHASE. 
 
 

 

YOUR CO ALARM WARRANTY 

This CO Alarm, excluding battery, is warranty to be free from defects in 
materials and workmanships under normal residential use and service 
for a period of (3) years from the date of purchase. The company will not 
be obligated to repair or replace parts that are found to be in need of 
repair because of misuse, damage or alterations occur after the date of 
purchase.  Send the CO Alarm with proof of purchase, postage and 
return postage prepaid, to local distributor.  The liability of the company 
arising from the sale of this CO Alarm shall not in any case exceed the 
cost of replacement of the product and in no case shall the company be 
liable for consequential loss or damages resulting from the failure of the 
product. 
 

HISPEC ELECTRICAL PRODUCTS LTD. SHALL HAVE NO 

LIABILITY FOR ANY PERSONAL INJURY OR PROPERTY 
DAMAGE, OR ANY SPECIAL INCIDENTAL, CONTINGENT 

OR CONSEQUENTIAL DAMAGE OF ANY KIND RESULTING 
FROM A FIRE. THE EXCLUSIVE REMEDY FOR BREACH OF 

THE LIMITED WARRANTY CONTAINED HEREIN IS THE 
REPAIR OR REPLACEMENT OF THE DETECTIVE 

PRODUCT AT HISPEC ELECTRICAL PRODUCTS LTD. 
OPTION. IN NO CASE SHALL HISPEC ELECTRICAL 

PRODUCTS LTD.’S LIABILITY UNDER ANY OTHER 
REMEDY PRESCRIBED BY LAW EXCEED THE PURCHASE 

PRICE. YOUR HEAT ALARMS IS NOT A SUBSTITUTE FOR 
PROPERTY, DISABILITY, LIFE OR OTHER INSURANCE OF 

ANY KIND. APPROPRIATE COVERAGE IS YOUR 
RESPONSIBILITY. CONSULT YOUR INSURANCE AGENT. 

 
This does not affect your statutory rights. 

This alarm is only suitable for residential dwellings and is not 
suitable for commercial or industrial use. 

 

Waste electrical products should not be disposed of with normal 
household waste. Please recycle where facilities exist. Check 

with your Local Authority or retailer for recycling advice. New 
regulation will encourage the recycling of Waste from Electrical 

and Electronic Equipment (European "WEEE Directive" 
effective August 2005). 

 

Hispec Electrical Products Ltd 
www.hispec.co.uk

 

 

Отзывы: