MH-012  Ecomaster Clima user manual  

 

7/7 

2.

 

Autochecking - error codes. 

When the system receives the signal from the battery disconnector (+30), it first checks the outlets to check 

what charges are applied and to make sure there is no short-circuit. 

It also checks the status of the probes. 
If any anomaly is detected, it will indicate the error(s) on the Display using the following codes: 

 

CODE

 

ERROR

 

INT

 

Internal Temperature Sensor Shorted or Open

 

ICE

 

Ice Temperature Sensor Shorted or Open

 

CHN

 

Channel Shorted or Open

 

EXT.

 

External Shorted or Open

 

MP

 

Main Outlet Pump Shorted

 

FP

 

Recirculation Pump Shorted

 

CMP

 

Compressor Outlet Shorted

 

RV

 

Roof Valve Outlet Shorted

 

FV

 

Floor Valve Outlet Shorted

 

S1

 

Heater Outlet Shorted Speed 1

 

S2

 

Heater Outlet Shorted Speed 2

 

PRF

 

Recirculation Flaps Outlet Shorted

 

DRF 

Defroster Recirculation Flap Outlet Shorted 

RB

 

Right Adjustable Evaporator Ventilator Outlet Shorted

 

LB

 

Left Adjustable Evaporator Ventilator Outlet Shorted

 

CNDB 

Adjustable Condenser Ventilator Outlet Shorted 

EVAP1

 

Evaporator Ventilator Outlet Shorted Speed 1

 

EVAP2

 

Evaporator Ventilator Outlet Shorted Speed 2

 

EVAP3

 

Evaporator Ventilator Outlet Shorted Speed 3

 

CND

 

Condenser Blower Outlet Shorted

 

C1

 

Underfloor Heater Outlet Shorted Speed 1

 

C2

 

Underfloor Heater Outlet Shorted Speed 2

 

POT.

 

Error in the automatic setting of the POT

 

VT MOT 

No return or the motorized roof valve is not connected. 

VS MOT 

No return or the motorized floor valve is not connected. 

NO 

ERROR 

No errors during checking process 

 

If any of the above errors appears, the Ecomaster Clima will start to operate in accordance with the default 

operating programme. It is possible that the vehicle’s interior temperature may not be regulated correctly under 
these conditions so it is recommended that the system should be reviewed by technical service personnel. 

Error detected by control once the initial system checking is performed may be consulted by entering View-

ing  or Diagnosis modes and then simultaneously pressing the 

(6) and 

(4) keys. 

 

Содержание Ecomaster Clima MH-012

Страница 1: ...Ecomaster Clima user manual Reference MH 012 ...

Страница 2: ...V1 09 23 05 Juan Bernal The new features corresponding to software version 1 0 are added to the manual From this version on it will be possible to control a motorized valve for the roof and floor heating circuit It now includes the possibility of programming the strictness of the filter applied to the reading from the temperature sensors V2 10 21 05 Juan Bernal Comments added V3 10 10 18 Pablo Gar...

Страница 3: ...al description 4 Temprature set 4 1 1 Varying the speed of the Evaporator Ventilators 4 1 2 Changing the flap position 5 1 3 Activation of ECO 5 1 4 Activation of De humidification Reheat 5 1 5 Check Temperatures 5 1 6 Variation of Contrast and Brightness 6 1 7 2 Autochecking error codes 7 ...

Страница 4: ...orced chill mode LO and acti vates its maximum cooling power the screen displays LO When the temperature is set above 27ºC 82ºF the system engages forced heat mode HI and activates its maximum heating power the screen displays HI Varying the speed of the Evaporator Ventilators 1 2 The speed of the evaporators can be varied from levels 1 to 3 When the speed is altered the system goes into manual mo...

Страница 5: ...s operating in air conditioning mode and the interior temperature is 2ºC higher than that selected Set the flaps will switch to Automatic mode and will close Activation of ECO 1 4 If the 4 key is pressed the letters ECO will appear on screen and the compressor will be disconnect ed The system switches into Semi automatic mode Pressing the 4 key will have no effect if the system is not working in D...

Страница 6: ...e the air conditioning unit is switched on For this purpose it is necessary to use the following key combination in which the first key pressed must be held down while the second key is pressed several times in succession to raise or lower the parameter in question 2 8 Greater brightness 2 7 Less brightness 3 8 Greater contrast 3 7 Less contrast 2 3 Factory settings for brightness and contrast ...

Страница 7: ...LB Left Adjustable Evaporator Ventilator Outlet Shorted CNDB Adjustable Condenser Ventilator Outlet Shorted EVAP1 Evaporator Ventilator Outlet Shorted Speed 1 EVAP2 Evaporator Ventilator Outlet Shorted Speed 2 EVAP3 Evaporator Ventilator Outlet Shorted Speed 3 CND Condenser Blower Outlet Shorted C1 Underfloor Heater Outlet Shorted Speed 1 C2 Underfloor Heater Outlet Shorted Speed 2 POT Error in th...

Отзывы: