Hisense BD-262WY Скачать руководство пользователя страница 19

 

18 

b, lower temperature of discharging. 

2.NO COOL 
(Popular failure reasons are below): 

Reason 

analysis 

Solutions: 

1) Leakage of gas 

Phenomenon of failure: 
a, leaking fast 
b, leaking slowly 
c, no voice of liquid flowing 
d, cut off charging tube, no gas goes 
out. 

First find out the point of leaking on tube, and 
then sealed it, vacuuming it, finally recharge 
with gas.   
Note

 

If you find oil on somewhere, it is possible that 
leakage point is there.   

2)There is some thing 
that blocked the liquid 
cycle system 

A,Ice blocking 
Sometime because unknown reason 
water comes into liquid cycle 
system, the capillary will be blocked 
by water after unit runs for period of 
time. 
Phenomenon of failure: 
The unit works well in the inception, 
after period of time the ice appears 
in the capillary and becomes more 
and more, till blocks the hole of 
capillary completely. In the moment 
you can find the ice on the 
evaporator defrosts. The noise of 
liquid flow disappears. The pressure 
of absorbing becomes negative.     
The phenomenon above will appear 
again and again. 
The way to check ice blocking: 
Warm the capillary with a hot towel, 
after a while the ice in the capillary 
melt, you can hear a sound of gas 
flow comes from the capillary 
abruptly. The pressure of absorbing 
becomes higher. It is Ice blocking. 

First stop unit for several minutes, and then 
open charging tube, discharge all of gas. Blow 
the cycle system with gas of nitrogen, and then 
recharge Gas, finally sealed the system.   

B, there is offal block the capillary   
Phenomenon of failure: 
If the capillary is blocked by 
something such as offal etc., the 
sound of liquid flow disappears.   
The ice on the evaporator defrosts 
The pressure of absorbing becomes 
negative. 
Higher temperature of discharging 
tube 
The way to check offal blocking: 
If you warm capillary with the way of 

First stop unit for several minutes, and then 
open charging tube, discharge all of gas. Blow 
the cycle system with gas of nitrogen. Change 
a new capillary and filter, and then recharge 
Gas, finally sealed the system. 

Содержание BD-262WY

Страница 1: ...Refrigerator Service manual NO FROST Model RS 34WC BD 262WY NOTE product specifications are subject to change...

Страница 2: ...temperature sensor 8 The instruction of replacing evaporator temperature sensor and temperature fuse and heater 8 The instruction of replacing PTC Starting relay and Overload protector 9 The instructi...

Страница 3: ...2 Circuit diagram...

Страница 4: ...3 Cooling diagram...

Страница 5: ...4 Display controls...

Страница 6: ...5...

Страница 7: ...6...

Страница 8: ...instruction of replacing the main board and display board Unscrew the back cover screws Remove the electron box cover and replace the main board The instruction of of replacing fan motor Remove the wi...

Страница 9: ...n motor The instruction of replacing temperature sensor Open air duct Board And take out sensor The instruction of replacing evaporator temperature sensor and temperature fuse and heater The instructi...

Страница 10: ...lay and Overload protector 1 The location of the PTC Starting relay and Overload protector 2 Disconnect the connecting wire of the PTC Starting relay and Overload protector The instruction of replacin...

Страница 11: ...10 The instruction of replacing Display board 1 The location of the display board 2 Unplug the display board wires and remove the screws fixing...

Страница 12: ...11 Installing your new appliance...

Страница 13: ...12...

Страница 14: ...13...

Страница 15: ...14...

Страница 16: ...PCB 3 Change the display PCB 4 The freezer digital display window show EF 1 The Fan motor is open circuit or short circuit 2 The Fan motor is bad 3 The control PCB is bad 1 Using a Multimeter with the...

Страница 17: ...3Whether the internal accessory of the refrigerator is in the right place 5 4Whether the water plate of compressor is fall from the unit 5 5 Does the tube of the refrigeration system bump each other...

Страница 18: ...for several minutes and then open charging tube discharge all of gas Change a new filter and then recharge gas finally sealed the system 3 There is air in the liquid cycle system The air in system wi...

Страница 19: ...The noise of liquid flow disappears The pressure of absorbing becomes negative The phenomenon above will appear again and again The way to check ice blocking Warm the capillary with a hot towel after...

Страница 20: ...al of door is damaged Replace the gasket 4 Too much food in the refrigerator Please put the food properly 5 Wind door is broken Replace wind door 6 Fan motor is broken Replace fan motor NOTE Before do...

Отзывы: