Piping

The unit can control a three way revert valve ( VXV ). When daily hot
water are required the three way revert valve ( VXV ) will have the priority
to revert to the hot water tank (VVB ). After the daily hot water reach its set
temperature the three way revert valve ( VXV ) return to its normal heating
circulation.

,

,

ELK

P1

FI

ET

ST

RT

A

HT

VVB

SAK

FL

F

EXP

FS

OT

PT

Outdoor unit

Indoor unit

B

AB

VXV

LPS

HPS

Name

Description

Included

Name

Description

Included

P1

Circulation pump

Internal (Option)

RT

Inlet water temperature sensor

Internal

ELK

Electric heater

Internal (Option)

ST

Out water temperature sensor

Internal

VXV

3 way Valve

Internal (Option)

OT

Outdoor temperature sensor

Internal

VVB

Hot water tank

External

HT

Hot water temperature sensor

Internal

FI

Soft joint

External

ET

suction gas temperature sensor

Internal

FS

Automatic water supplement valve

External

HPS

High pressure transmitter

Internal

SAK

Safety valve

External

LPS

Low pressure transmitter

Internal

FL

Filter

External

PT

Exhaust gas temperature sensor

Internal

F

Differential pressure flow switch

Internal

EXP

Diaphragm expansion vessel

External

Содержание AW13

Страница 1: ...Guangzhou Hiseer Air Conditioning Co Ltd www chinaheatpump com Split EVI Air to Water Low Temp Heat Pump ...

Страница 2: ...water temperature varies according to ambient temperature Most components are well sealed to retain heat and prevent dripping L Features Triple functions Heating cooling and produce domestic hot water Outdoor unit Contains two fans blades and motors and aluminum finned copper coil heat exchanger Outdoor unit has not pre filled refrigerant Indoor unit Contains Hitachi EVI R410A compressor High effi...

Страница 3: ... injection inlet and then injecting mixing and compressing process goes on at the same time until working room separates from injection inlet The gas state in working room change to state 2 from state 2 3 After working room separates from injection inlet the gas inside is compressed from state 2 to state 3 3 is normal heat pump Heat output increases almost in linear trend following the increase of...

Страница 4: ...mption at 10 45 kW 9 4 4 8 Heat output Power consumption at 15 35 kW 8 6 3 9 Heat output Power consumption at 15 45 kW 8 5 4 8 Starting current A 55 Power 380 415V 3PH 50Hz Compressor HITACHI scroll Condenser Brazed plate heat exchanger Nominal flow heating medium l s 0 67 Internal pressure drop at nominal flow kPa 24 Air flow m 3 h 5000 Nominal output fan W 300 Max outgoing heating medium tempera...

Страница 5: ...Performance curve Ambient temp Ambient temp 1 Flow temperature 35 Full load 2 Flow temperature 45 Full load Heating performance curve Ambient temp ...

Страница 6: ...Dimension Outdoor unit Indoor unit ...

Страница 7: ...Water pressure drop Optional internal water pump curve m3 h 10 20 30 1 0 2 0 3 0 4 0 40 KPa AW13 F 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 Pressure mCE Flow m3 H Maximum speed Medium speed Mini speed ...

Страница 8: ...Circulation pump Internal Option RT Inlet water temperature sensor Internal ELK Electric heater Internal Option ST Out water temperature sensor Internal VXV 3 way Valve Internal Option OT Outdoor temperature sensor Internal VVB Hot water tank External HT Hot water temperature sensor Internal FI Soft joint External ET suction gas temperature sensor Internal FS Automatic water supplement valve Exter...

Отзывы: