background image

Description and operating instructions
Industrial ETHERNET Rail Switch 2 Family

RS2-4R

The Rail Switch RS2 has been especially
designed for use in industrial environments.
It supports ETHERNET 10 MBit/s and Fast
ETHERNET 100 MBit/s.

The RS2-4R devices 
– RS2-4R 
– RS2-4R 1MM SC 
– RS2-4R 1SM SC 
– RS2-4R 1LH SC 
– RS2-4R 2MM SC 
– RS2-4R 2SM SC 
– RS2-4R 2LH SC
are manageable. They support SNMP and
Web based management.

The Rail Switch devices support switched
ETHERNET networks in accordance with
IEEE standard 802.3 using copper technolo-
gy or optical waveguide (F/O), in line and
ring structures. The switch devices are plug-
ged onto the standard bar.

Depending on the model, the RS2-4R devi-
ces have two to four 10/100 Mbit/s twisted
pair (TP/TX) ports (RJ45 connectors) and up
to two fiber optic ports (100 Mbit/s ports).
The fiber optic ports to connect further
more switches are available with FX interfa-
ces (depending on the RS2-4R model with
multimode, singlemode or Long Haul, DSC
connectors):
– RS2-4R:

4 x TP/TX

– RS2-4R 1…: 3 x TP/TX, 1 x FX
– RS2-4R 2…: 2 x TP/TX, 2 x FX

It is possible to connect data terminal
equipments or other network segments to
the 10/100 Mbit/s ports using twisted pair
cabling TP/TX. The ports support auto-
negotiation, autopolarity and autocrossing.

The RS2-4R devices in addition have one
V.24 interface for external management.

In the„RS2-4R Management Manual – Indu-
strial ETHERNET Rail Switch 2“ you find a
detailled description on the RS2-4R Rail
Switch.

F

, the Hirschmann network manage-

ment system, is the optimum management
solution for this product. Your sales partner
keeps information ready.

RS2-4R

RS2-4R 1MM SC 
RS2-4R 1SM SC 
RS2-4R 1LH SC 

RS2-4R 2MM SC 
RS2-4R 2SM SC 
RS2-4R 2LH SC

Содержание RS2-4R

Страница 1: ...nectors and up to two fiber optic ports 100 Mbit s ports The fiber optic ports to connect further more switches are available with FX interfa ces depending on the RS2 4R model with multimode singlemod...

Страница 2: ...with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and corr...

Страница 3: ...applied to the device as described in the operating instructions z Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel th...

Страница 4: ...S2 4R runs a hard ware self test During operation an integra ted watch dog monitoring unit monitors the function of the software Reset The RS2 4R will be reset by the following actions management inpu...

Страница 5: ...lduplex 1 0 Ring port 100 Mbit s fulldupl off 1 1 Ring port 100 Mbit s fulldupl on Tab 1 DIP switch function 1 9 INTERFACES 10 100 MBit s connection Twisted Pair 10 100 Mbit Ports 8 pin R45 sockets al...

Страница 6: ...00 you can close the two ends of a line structured backbone to form a redundant ring The RS2 4R is integrated into the ring via the HIPER Ring ports ports 3 and 4 Within a redundant ring any mixture o...

Страница 7: ...m version 5 5 on Note The Web based interface uses the plugin Java runtime environment version 1 3 If this is not installed on your compu ter an installation via the internet is started automatically...

Страница 8: ...4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6...

Страница 9: ...supply voltage 2 present 1 x red LED FAULT indicator contact is open and indicates error 1 x green yellow LED RM redundancy manager autoconfig adapter Port status 4 x green LED LS 1 to 4 link state 4...

Страница 10: ...nd Network Solutions Stuttgarter Stra e 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 49 7127 14 1551 E Mail ans support hirschmann de Internet http www hirschmann com Printed in Germ...

Отзывы: