7 Technical Data
44
Version 04 05/2014
44
OZD Profi 12M … PRO
P11
G11
G11-1300
P12
G12
G12-1300
G12-EEC
G12-1300 EEC
Transmission distance
–
with glass fiber E 10/125 (Default)
(0.5 dB/km)
–
–
0 - 15 000 m
1)
–
with glass fiber G 50/125 (Default)
(860 nm: 3.0 dB/km; 1310 nm: 1.0 dB/km)
–
0 - 3 000 m
1)
0 - 10 000 m
–
with glass fiber G 62.5/125 (Default)
(860 nm: 3.5 dB/km; 1310 nm: 1.0 dB/km)
–
0 - 3 000 m
1)
0 - 10 000 m
–
with PCF fiber S 200/230
(660 nm: 10.0 dB/km; 860 nm: 8.0 dB/km)
0 - 400 m
1),4)
0 - 1 000 m
5)
–
0 - 800 m
2)
for 12 Mbit/s
5)
–
with PCF fiberr S 980/1000
(0.2 dB/m)
Transmitting power ”Reduced“
0 - 50 m
–
–
Transmitting power ”Default“
0 - 80 m
–
–
Optical connector
BFOC/2,5
Electromagnetic compatibility (EMC)
Interference immunity for industry in accordance
with EN 61000-6-2:2001
Electrostatic discharging (ESD)
conforms to EN 61000-4-2; 4 kV contact discharge, 8 kV
air discharge
Electromagnetic field
conforms to EN 61000-4-3; 10 V/m (80 MHz - 1000 MHz,
1400 MHz -2000 MHz)
Fast transients (burst)
conforms to EN 61000-4-4; 2 kV power line, 1 kV data line
Voltage surge
conforms to EN 61000-4-5; 1 kV data line,
1 kV power line symmetrical,
1 kV power line asymmetrical
Line-conducted interference voltages
conforms to EN 61000-4-6; 10 V (150 kHz - 80 MHz)
Emitted interference
conforms to EN 55022; Class A
conforms to FCC CFR47 Part 15; Class A
Climatic ambient conditions
Ambient temperature
OZD Profi 12M ... PRO without “EEC“ feature“ 0 °C to + 60 °C
OZD Profi 12M G12(-1300) EEC PRO
3)
– 20 °C to + 60 °C
(IEC 68-2-1, IEC 68-2-2)
Storage temperature
– 40 °C to + 70 °C (IEC 68-2-14)
Relative humidity
< 95 %, non-condensing (IEC 68-2-30)
100 %, condensing for OZD … G12-EEC PRO
1)
(IEC 68-2-30)
Air pressure
during operation: up to 2000 m (795 hPa)
transport and storage: up to 3000 m (700 hPa)
Contamination level
2
1) The specified distance allowed between two OZD Profi must not be exceeded regardeless of the optical power budget.
2) With a fiber bandwidth length product of 17 MHz
.
km.
3) The OZD Profi 12M G12(-1300) PRO can also be supplied in a special design for more severe environmental conditions. This variant is
designated the OZD Profi 12M G12(-1300) EEC PRO.
The DIL switches on the OZD Profi 12M G12(-1300) EEC PRO may also only be operated at ambient temperatures between 0 °C and + 60 °C.
4) Transmitting power Default
5) Transmitting power Reduced