28
Installation OpEdge-8D
Release 01 10/2022
2.6.2
1000 Mbit/s F/O port (optional)
Verify that you connect LH ports only with LH ports, SX ports only with SX
ports, and LX ports only with LX ports.
Connect the data cables according to your requirements.
See “Ethernet ports” on page 18.
2.7
Filling out the inscription label
The information field for the IP address helps you identify your device.
2.8
Making basic settings
Note:
2 or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Graphical User Interface
Command Line Interface via COM2 port
To configure basic settings, connect to the OpEdge webpage. The default IP
address of Ethernet port 1 is 192.168.0.250. The login URL is
https://
192.168.0.250:8080
Further information on the basic settings of the device can be found in the
software user documentation.
Default settings
DB9 port data rate: 115200 Baud
Ethernet ports: link status is not evaluated (signal contact)
Optical ports: Full duplex
TP ports: Autonegotiation
2.8.1
First Login (Password)
To help prevent undesired access to the device, it is imperative that you
change the default password during initial setup.