Installation OCTOPUS OS20/OS24 Unmanaged
Release 07 07/2014
23
2.2.1
Devices with operating voltage type A
For the supply voltage, the following applies:
Operating voltage
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl. maximum tolerances
9,6 V ... 60 V
The input voltage is electrically isolated from the housing.
The device provides for voltage supply redundancy with no load
distribution.
The supply voltage is connected via a 5-pin M12 connector (A coding, e.g.
ELWIKA 5012 PG7 from Hirschmann, supplied).
Connect the supply voltage lines.
WARNING
ELECTRIC SHOCK
The nominal voltage of 48 V specified for trains can temporarily exceed the
SELV threshold of 60 V based on EN 50155 para. 5.1.1.1. Use additional
measures to limit the surge voltage to 60 V or use a lower nominal voltage.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
Figure
Pin
Function
1
+ 24 ... 48 V DC (1)
2
Not used
3
0 V
4
+ 24 ... 48 V DC (2)
5
Not used
Table 11: Pin assignment of the 5-pin M12 socket for connecting the supply voltage