Installation MACH1000
Release 06 03/2021
3
Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the HiDiscovery or Industrial
HiVision application
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP (Option 82)
AutoConfiguration Adapter
You will find more information in the “Basic Configuration User Manual”.
You find these manuals as PDF files on the Internet at
http://
www.doc.hirschmann.com
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation
Ring manager disabled
Stand-by coupling: disabled
Port 4 = control port, port 3 = coupling port for redundant Ring coupling