Fault
code
Error
Cause
Elimination
EB1
Below lower limit value
in measuring channel
"rope length on the
winch”
•
No rope on the winch
(* only EB1)
•
No sensor for winch measuring
available
•
rope length not calibrated
•
wrong rope/winch parameters
in data-programming
•
counter input not define in con-
figuration
•
counter input defective
•
calibrate rope length
•
mount sensor or turn off this
function in the data-
programming
•
calibrate rope length, layer
•
check parameter in the
data-programming
•
change I/O configuration
•
change Iflex
EB2
Upper limit value in
measuring channel "
rope length on the
winch" has been ex-
ceeded.
•
Rope completely rolled up on
winch (* only EB2)
•
Refer to EB1
•
calibrate rope length
•
Refer to EB1
EB3
Upper limit value in
measuring channel
"hook height" has been
exceeded.
•
No rope length between front
sheave and hook
•
Refer to EB1
•
Refer to EB1
EDD
Battery empty
•
Battery check detected a low
voltage of the battery
•
change and setup battery
•
Temporary: Press alarm off
button to work without data-
logger
EFD
LMI Watchdog extra
time
•
Function requires more than 0.5
seconds to activate, e.g.
write flash PROM
•
Message is deactivated
automatically after process-
ing
Note:
If a fault message is displayed that is not included in the present list, then please contact
your local Hirschmann Customer Service. >
www.hirschmann-
usa.com <