Commissioning
4.2 Status
LEDs
There are 10 LEDs on the front panel of the device, which indicate the status of various operating
conditions.
The meaning of the signals can be taken from the table below. The signals apply only to normal
operation; deviating signals apply to programming mode:
off:
lights:
flashes:
No supply
voltage present
Supply voltage is
present
Hoist limit switch has
triggered
or
radio link to a wire-
less hoist limit switch
interrupted
During the system diagnosis
No sensor
registered to
this channel
Sensor registered to
this channel and
ready for operation
During the registration of new
wireless sensors
or
hoist limit switch on the indi-
cated channel is in ‘sleep’ mode
or
link with the sensor on the indi-
cated channel is interrupted
Batteries of the wire-
less sensor on this
channel are almost
exhausted!
(capacity < 6.5 %)
Replace the batter-
ies soon!
Table 2
Overview of status LED
© 2010 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · E-mail: [email protected]
19
/37