Diagnostics
[ Diagnostics > Ports > Port Monitor ]
277
RM GUI GRS
Release
8.0
09/2019
[
Auto-disable
]
In this tab, you activate the
Auto-Disable
function for the parameters monitored by the
Port Monitor
function.
Table
Reason
Displays the parameters monitored by the
Port Monitor
function.
Mark the adjacent checkbox so that the
Port Monitor
function carries out the
auto-disable
action if
it detects that the monitored parameters have been exceeded.
Auto-disable
Activates/deactivates the
Auto-Disable
function for the adjacent parameters.
Possible values:
marked
The
Auto-Disable
function for the adjacent parameters is active.
If the adjacent parameters are exceeded and the value
auto-disable
is specified in the
Action
column, then the device carries out the
Auto-Disable
function.
unmarked
(default setting)
The
Auto-Disable
function for the adjacent parameters is inactive.
Buttons
You find the description of the standard buttons in section
Reset
Enables the port highlighted in the table again and resets its counter to
0
. This affects the counters
in the following dialogs:
Diagnostics > Ports > Port Monitor
dialog
–
Link flap
tab
–
CRC/Fragments
tab
–
Overload detection
tab
Diagnostics > Ports > Auto-Disable
dialog
[
Link flap
]
In this tab, you specify individually for every port the following settings:
The number of link changes.
The period during which the
Port Monitor
function monitors a parameter to detect discrepancies.
Содержание GREYHOUND GRS1020
Страница 8: ......
Страница 16: ......
Страница 146: ......
Страница 232: ......
Страница 310: ......
Страница 330: ......
Страница 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Страница 339: ......
Страница 340: ......
Страница 350: ......
Страница 354: ......
Страница 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Страница 618: ......
Страница 619: ......