Hirschmann Dragon PTN Series Скачать руководство пользователя страница 12

2.3

 

Onboard Interfaces

 

See Figure 8 for a side view of the IFM module. 

 

2.3.1

 

Straps

 

No user relevant straps. 

 

2.3.2

 

DIP Switches

 

a.

 

Hardware Edition

 

The  Hardware  Edition  is  set  in  decimal  code  using  rotary  switches  S2  to  S3  (=most 

significant).  It can be read out as well via HiProvision. This edition has been factory set and 

MUST NOT BE CHANGED! 
Example: Setting S3=’0’ and S2=’5’ indicates Hardware Edition ‘5’ (dec). 

 

 

Figure 9 Hardware Edition

 

 

b.

 

E1/T1 Configuration

 

The  E1/T1  configuration  of  the  2-OLS  module  is  factory  set  by  the  S1  DIP  switch  into  E1 

mode and must not be changed. The configuration can be read out via HiProvision. 

    

Switch  =  E1:  both  E1/T1   ports  operate  as  E1  ports,  use  the  ‘2-OLS-E1-L’  IFM  in 

HiProvision; 

    

Switch = T1 (=future): both E1/T1 ports operate as T1 ports, use the ‘2-OLS-T1-L’ IFM in 

HiProvision. 

 

 

 

 

Figure 10 E1/T1 Configuration

 

E1 

E1/T1 

Configuration 

T1 

SW2 

SW3 

SW4 

SW5 

SW6 

SW7 

SW8 

12 

Interface Module PTN-2-OLS with E1/PTN-2-OLS with T 

Release 01 02/2018 

 

Содержание Dragon PTN Series

Страница 1: ...anual Installation Dragon PTN Interface Module PTN 2 OLS with E1 PTN 2 OLS with T1 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T1 Technical Support Release 01 02 2018 https hirschmann support belden com ...

Страница 2: ...ave been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no re...

Страница 3: ...al Switching Module CSM 11 2 2 8 Test and Loopback Selftests 11 2 3 Onboard Interfaces 12 2 3 1 Straps 12 2 3 2 DIP Switches 12 3 MODULE SPECIFICATIONS 13 3 1 General Specifications 13 3 2 Other Specifications 13 3 3 Ordering Information 13 4 ABBREVIATIONS 13 List of figures Figure 1 2 OLS SDH Example 5 Figure 2 Front Panel 6 Figure 3 Optical Serial ST Connector 8 Figure 4 E1 RJ 45 Connector 8 Fig...

Страница 4: ... 6 Table 2 LED Indications In Boot Operation 7 Table 3 LED Indications In Normal Operation 7 Table 4 E1 RJ 45 Connector Pin Assignments 8 Table 5 Other Specifications 13 4 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T Release 01 02 2018 ...

Страница 5: ...n side the 2 OLS receives the E1 traffic and converts it back to an optical low speed serial signal towards the end application In HiProvision Dragon PTN Management an Optical Low Speed Serial service can be configured between two optical ports each port located in a different node This service bundles together 32 TDM Time Division Multiplex connections resulting in a total bandwidth of 2 048 Mbps...

Страница 6: ... refers to the manual issue All these manuals can be found in the HiProvision Dragon PTN Management System Help function Table 1 Manual References Ref Number Title 1 DRA DRM821 Dragon PTN and HiProvision Operation 2 DRA DRM801 Dragon PTN Installation and Operation 3 DRB DRM802 Dragon PTN Nodes PTN2210 PTN2209 PTN2206 PTN1104 4 DRB DRM803 Dragon PTN Switching Module PTN CSM310 A 5 DRA DRM810 Dragon...

Страница 7: ...2 x Fast blinking 3 x 4 x Fast blinking x x x x x LED is lit LED is not lit The sub cycle times may vary The entire boot cycle time 1 4 takes approximately 2 minutes Table 3 LED Indications In Normal Operation LED Color Status PI Power Input Not lit dark 12V power input to the board not OK Green 12V power input to the board OK PF Power Failure Not lit dark power generation on the board itself is O...

Страница 8: ... 2 OLS module provides two optical serial ports with each port having two ST Straight Tip connectors TX and RX These ports can be used for communication over optical fiber Figure 3 Optical Serial ST Connector 2 1 4 E1 RJ 45 Ports Copper and Cables The 2 OLS module provides two E1 ports and each port connector has eight pins Each port provides one tip ring pair See the table and figure below for an...

Страница 9: ... for E1 HDB3 is an enhancement of AMI For this reason AMI is mentioned here as well As the E1 link has no separate clock transmission the receiver will derive the clock from the incoming data stream A minimum density of logical ones is required in order to guarantee a faultless clock recovery This is achieved basically by AMI which encodes the data stream with bipolar violations A more enhanced an...

Страница 10: ...the optical serial RX ports FM0 encoded data is generated at the optical serial TX ports 2 2 5 Short Haul Long Haul on E1 Ports Long E1 links 200m Long Haul have more signal attenuation than shorter links 200m Short Haul As a result the signal levels or sensitivity 0 or 1 on the receiver side must be configured according the used link Long Haul or Short Haul In HiProvision a Short Haul parameter c...

Страница 11: ... will operate as well because 2 OLS samples at 6 6 times the selected bitrate E1 Ports Short Haul see 2 2 5 unchecked default checked 2 2 7 I O with the Central Switching Module CSM The CSM is only needed to program the 2 OLS IFM via HiProvision Once the 2 OLS IFM has been configured it does not need the CSM anymore 2 2 8 Test and Loopback Selftests Test and Loopback selftests can be performed via...

Страница 12: ...tes Hardware Edition 5 dec Figure 9 Hardware Edition b E1 T1Configuration The E1 T1 configuration of the 2 OLS module is factory set by the S1 DIP switch into E1 mode and must not be changed The configuration can be read out via HiProvision Switch E1 both E1 T1 ports operate as E1 ports use the 2 OLS E1 L IFM in HiProvision Switch T1 future both E1 T1 ports operate as T1 ports use the 2 OLS T1 L I...

Страница 13: ...3 Ordering Information 2 OLS with E1 future support 2 OLS with T1 future support 4 ABBREVIATIONS AIS Alarm Indication Signal AMI Alternate Mark Inversion CE Conformité Européenne CSM Central Switching Module DC Direct Current EMI ElectromagneticInterference ERR Error ETH Ethernet FLT Fault HDB3 High Density Bipolar of Order 3 IEEE Institute of Electrical and Electronics Engineers IFM InterFace Mod...

Страница 14: ...Time Between Failures OLS Optical Low Speed PF Power Failure PI Power Input PTN Packet Transport Network PTP Point to Point RAI Remote Alarm Indicator SDH Synchronous Digital Hierarchy SF Super Frame ST Straight Tip TDM Time Division Multiplex 14 Interface Module PTN 2 OLS with E1 PTN 2 OLS with T Release 01 02 2018 ...

Отзывы: