Hirschmann 943 739-001 Скачать руководство пользователя страница 11

11

6. Technical Data

General data

MACH 3001 Chassis

MACH 3001

Chassis with built-in basic board M-BASIC4, power supply unit and 4 fans;
for up to 4 media modules, up to 2 external 24VDC power supply units

Integrated power supply unit:

Operating voltage 

230/120VAC (85VAC to 264VAC)

Input frequency 

50/60 Hz (47Hz to 63Hz)

Current input 

0.9 A(230VAC); 1.8A (120VAC)

Power failure bridging 

> 20 ms

Cosine phi at maximum load 

0.98

Activation current 

Max. 40 A

Fuse

Built into the power supply unit
Fuse of the 16 A power supply network, B characteristic

24VDC inputs at back:

Operating voltage 

24VDC (-20% +33%) Safety Extra Low Voltage (SELV) 
(redundant inputs uncoupled, with reverse polarity protection)
0 Volt connection of the 24VDC input plug(back) is connected to chassis!

Buffer time 

Min. 10 ms at 24VDC

Current consumption with media modules 

Max. 6.9 A at 24VDC

Overload current protection at input

Non-changeable thermal fuse

Recommendation 

Protect every power supply unit in a device via its own power circuit

Required power

MACH 3001 

40 W

M-FAST 8MM-MT 1

6 W

M-PSU1 

60 W

M-GIGA 1LH-SC 

8.5 W

M-BASIC 4 

50 W

M-GIGA 1LX-SC 

8.5 W

M-ETH 4MM-ST 

8 W

M-GIGA 2LH-SC 

10 W

M-FAST 8TP-RJ 

10 W

M-GIGA 2LX-SC 

10 W

M-FAST 2LH-SC 

7.5 W

M-GIGA 2SX-SC 

10 W

M-FAST 2MM-SC 

7.5 W

M-GIGA 2TP-RJ 

10 W

M-FAST 2SM-SC 

7.5 W

M-Router

5 W

Dimensions W x H x D

482.6 mm (= 19 ") x 88.1 mm (= 2 HE) x 515 mm

Mass (state of delivery)

8.5 kg appox.

Ambient temperature

Surrounding air 0 ºC to + 50 ºC

+ 32 °F to + 122 °F

Storage temperature

Surrounding air - 20 ºC to + 80 ºC

- 4 °F to + 176 °F

Humidity

20% to 90% (non condensing)

Atmospheric pressure

up to 2000 m (795 hPa, higher altitudes on demand)

Laser protection

Class 1 conforming to EN 60825

Protection type

IP 30

Interference characteristics

EN 55022 Class A, CFR-47 Part 15, FCC, Class A

Specifications and standards
EMV

– Emission

– EN55022:Class A – Information technology equipment – Radio disturbance characteristics
– EN61000-3-2 
– EN61000-3-3 
– CFR-47 Part 15 – Code of Federal Regulations, FCC, Class A

– Immunity

– EN 61000-6-2 Generic standards – Immunity for industrial environments
– (EN61131-2 – Programmable Controllers) IEC 65B/421/CDV
– EN55024 – Immunity Limits for Power Ports

Security

– General 

– EN60950 – Safety of Information Technology Equipment (ITE)
– cUL505 – Safety of Industrial Control Equipment

– Laser protection

– EN60825-1

Certifications

cUL 508 /CSA C22.2 No.142

Interfaces of the media modules

M-ETH 4MM-ST

4 ports based on 10BASE-FL with BFOC sockets
transmission distance 2 km / 6,500 ft with multimode fiber 

M-FAST 8TP-RJ

8 ports based on 10BASE-T/100BASE-TX with RJ45 sockets (10/100 MBit/s)
transmission distance 100 m / 330 ft twisted pair

M-FAST 2LH-SC

2 ports based on 100BASE-FX with DSC sockets
transmission distance 80 km / 262,400 ft maximum (9 µm SMF, 1550 nm) 

M-FAST 2 SM-SC

2 ports based on 100BASE-FX singlemode with DSC sockets,
transmission distance 20 km / 65,000 ft with singlemode fiber

M-FAST 2 MM-SC

2 ports based on 100BASE-FX with DSC sockets,
transmission distance 2 km / 6,500 ft with multimode fiber

M-FAST 8 MM-MT

8 ports based on 100BASE-FX with MTRJ sockets,
transmission distance 2 km / 6,500 ft with multimode fiber

M-GIGA 1LH-SC

1 port based on 1000BASE-LX with DSC socket
transmission distance 70 km / 229,600 ft maximum (9 µm SMF, 1550 nm) 

M-GIGA 1LX-SC

1 port based on 1000BASE-LX with DSC socket
transmission distance 550 m / 1,800 ft (62,5 µm MMF*, 50 µm MMF*),10 km (9 µm SMF) 

M-GIGA 2LH-SC

2 port based on 1000BASE-LX with DSC socket
transmission distance 70 km / 229,600 ft maximum (9 µm SMF, 1550 nm) 

Содержание 943 739-001

Страница 1: ...connectors PSU2 PSU3 Integrated fans FAN1 to FAN4 Integrated basic board BOOT RUN MASTER SLAVE ERROR Media modules Link status Data Syn chronous Link status Data out Data In Router module Activity Tra...

Страница 2: ...erly and correctly Furthermore it must be operated and serviced carefully Safety Guidelines Power Supply For reasons of safety the fuse installed in the integrated power supply unit PSU1 must not be c...

Страница 3: ...delivered in a conducting ESD protective bag This packaging can be reused Be sure to observe the following precauti ons for electrostatic sensitive devices when handling the components Establish elec...

Страница 4: ...p to the management station The sending of such a trap can be stopped by the management 1 4 FURTHER FUNCTIONS AND FEATURES Reset The MACH 3001 is reset by the following events management insufficient...

Страница 5: ...ation on the ope rating status of the media modules The media modules have a number of LEDs per Port They have one or more of the follo wing LEDs LS DA Link Status Data green yellow LED not lit no lin...

Страница 6: ...supply units or single redundancy 1 internal and 1 external power supply unit or 2 external power sup ply units You can achieve enhanced redun dancy by means of a separate voltage supp ly input from...

Страница 7: ...finally pull the cover of the chassis forwards Remove the three screws Ensure that the screw in the middle of the free module slot see Fig 12 is screwed all the way down before you insert the module T...

Страница 8: ...allation of the MACH 3001 the following settings are necessary for cor rect operation of the management ground not connected 24VDC pin 3 pin 2 pin 1 24VDC connection socket for PSU2 and PSU3 safety co...

Страница 9: ...link status as well as the data traffic Three different 2 port Fast ETHERNET media modules are available M FAST 2LH SC singlemode for large distances M FAST 2SM SC singlemode for middle distances M F...

Страница 10: ...MAC address of the MACH 3001 and for executing Plug Play System Time This menu is for entering the system time Switching General This menu is for switching on off the Span ning Tree GVRP and GMRP Swit...

Страница 11: ...n Class 1 conforming to EN 60825 Protection type IP 30 Interference characteristics EN 55022 Class A CFR 47 Part 15 FCC Class A Specifications and standards EMV Emission EN55022 Class A Information te...

Страница 12: ...ts for the connection of router media modules 19 mounting angle 3 covering panels mounted rubber feet Order number MACH 3001 943 739 001 Media module M ETH 4MM ST 943 704 021 Media module M FAST 8TP R...

Отзывы: