Part No. 4801-3031 Rev.6-09
Page
3
of
22
Super Saver XL-120 Heater
HEATER DIMENSIONS
WEIGHT
130 lb. (60 kg)
HEIGHT
30 in. (76.2 cm)
WIDTH
24-1/2 in. (62.2 cm)
DEPTH
19-1/4 in. (48.9 cm)
Table Of Contents
1.
Specifications And Requirements..................4
2.
Warnings And Cautions .................................5
3.
Maintenance And Warranty ...........................6
4.
Installation......................................................7
5.
User Instructions ............................................8
6.
Outside Mount (Optional)...............................9
7.
Component And Wiring Diagram .................10
8.
Ladder Type Schematic Diagram ................11
9.
Servicing Instructions...................................12
10.
Pipe Sizing Guidelines.................................17
11.
Parts & Assemblies......................................19
MINIMUM CLEARANCES
Heater must be located a minimum of 12 inches (305 mm) from ceiling, a minimum of 12 inches (305 mm) from wall,
a minimum of 20 inches (305 mm) from ground, and positioned so that livestock are unable to come in contact with
heater or within 10 feet (3 meters) of hot air discharge. (See Figure 1 - Installation Instructions).
1.
Specifications And Requirements
Be Sure To Check Delivery
!
Locate packing slip and make sure
all of the listed parts are enclosed.
If not, call your Hired-Hand
Distributor immediately.
Adjustable Wrench
Gas Leak Testing Solution
Pipe Glue
1/4
″
(7 mm)
Nut Driver
Install screw hooks with hammer or drill.
Model No.
Maximum Input
Ventilation
(air required to support combustion)
SS-225-XL
225,000 BTUH (65.9 kW)
1000 CFM (1699 m
3
/hr)
LP/Propane
Gas
Maximum 14 in. W.C. (34.8 mbar) and minimum 12.5 in. W.C. (31.1 mbar) inlet gas supply
pressure acceptable at gas regulator connection. Burner manifold pressure 11 in. W. C. (27.4
mbar) at maximum input. Gas pressure should be checked by a certified gas technician while
heater is in operation.
Natural
Gas
Maximum 14 in. W.C. (34.8 mbar) and minimum 5 in. W.C. (12.5 mbar) inlet gas supply pressure
acceptable at gas regulator connection. Burner manifold pressure of 3.5 in. W. C. (8.7 mbar) at
maximum input. Gas pressure should be checked by a certified gas technician while heater is in
operation.
Refer to heater ratings plate for unit voltage, amperage, and frequency ratings.