The smoke sensor signal can be sent to alarm system or fire alarm system hub, through a NC 

 

Battery or VDC powered 

 

Built-in temperature sensor 

 

Automatic efficiency test performed every 5 seconds. 

Specifications

 

 

Radio protocol: Z-Wave 

 

Radio Frequency: 868.4MHz EU; 908.4MHz US; 921.4Hz ANZ; 869.2Hz RU 

 

Power supply: DC 12-24V 

 

Battery type

CR123A 

 

Power consumption

VDC operation

: 0.4W 

 

Output terminals maximum current carrying capacity

25mA 

 

Maximum voltage at output terminal: 24V(AC/DC) 

 

Operational Temperature: 0

-40

 

 

Measured Temperature: -20

-100

 

 

Range

up to 50m outdoors, up to 30m indoors (depending on the building materials used) 

 

Dimension

65mm x 28mm   

Installation Instructions 

It’s recommended to install the sensor on the ceiling or upper portion of wall at least 40cm from 

corners  and  other  objects.  Particular  attention  should  be  paid  toany  adjacent  objects  or  devices 

which can impede smoke’s access to it’s sensor.It’s recommended to install the sensor in all rooms 

prone to fire, and between such rooms as well. 

Содержание CT-SMZW2007-FBR

Страница 1: ...gh a NC normally closed contact terminal The optical sensor detects smoke at an early stage of fire often before flames appear and temperature starts to rise significantly Moreover the device has a built in temperature sensor which can also trigger the alarm once the specified temperature threshold is exceeded Smoke Sensor is designed to be placed on a wall or ceiling LED indicator signals fire op...

Страница 2: ...t terminals maximum current carrying capacity 25mA Maximum voltage at output terminal 24V AC DC Operational Temperature 0 40 Measured Temperature 20 100 Range up to 50m outdoors up to 30m indoors depending on the building materials used Dimension 65mm x 28mm Installation Instructions It s recommended to install the sensor on the ceiling or upper portion of wall at least 40cm from corners and other...

Страница 3: ...is hard wired to power source drill holes in sensor s cover Note the sensor may be connected to a wired alarm system controller or fire prevention system 3 Install the cover in desired location 4 If the sensor is to be VDC powered connect wires observing Fig 1 If the sensor is to be connected to alarm system connect wires observing Fig 2 5 Screw the smoke sensor into the cover 6 Include the module...

Страница 4: ...ci fied wake up intervals or at a manual wake up triple click B button In DC powering mode con figuration and association parameters are sent when necessary and additionally the smoke sensor serves as a Z Wave signal repeater Switching to a constant current powering mode 1 Exclude a sensor from the Z Wave network 2 Disconnect the battery 3 Install the constant power connecting terminal observing t...

Страница 5: ... 5 seconds 4 Please go to the device list interface and refresh the device list the device will not be dis played 5 If the device can still be displayed network exclusion failed repeat steps 2 4 NOTE If the device is online directly perform steps 1 5 if the device is offline need interruption of the device power supply first and then perform step 1 5 DEVICE RESET Reset procedure clears the modules...

Страница 6: ... with the understanding of wiring diagrams and knowledge of electrical safety should complete installation following the instructions Before installation please confirm the real voltage complying with the device s specification Cut off any power supply to secure the safety of people and device During installation protect the device from any physical damage by dropping or bumping If happened please...

Отзывы: