Specifications

 

1.

 

Radio protocol: Z-Wave 

2.

 

Radio Frequency: 908.42MHz 

3.

 

Power supply: 85 V-260V AC 

4.

 

Maximum load: maximum load 1 road, every road load 5A

 

5.

 

Installation method: wall-mounted (standard American box installation) 

6.

 

Dimension: 120mm × 75mm × 38mm 

Installation Instructions 

PRODUCT INSTALLATION 

CAUTION:   

Cut off power supply at circuit breaker or fuse before installation to avoid fire or shock! Neutral 

and live wire are required to put into the bottom box. 

 

1)

 

As shown in Fig.1, using the screwdriver to pry the gaps on the side of the switch, then open 

the panel. 

 

Fig.1 

2)

 

Using both hands to hold the switch panel and forcibly push up to remove the switch panel. 

3)

 

Follow the Fig.2 diagram to start wiring: 

 

 

Fig.2 

 

 

110-220V AC 

Содержание CT-LCZW5026-MH

Страница 1: ...ol as well as combines with other devices to do more settings such as scenarios linkage control The touch panel switch has a beautiful and concise appearance and for the US regulatory dimen sion and can be directly replaced the ordinary wall switch to reduce the cost and time of rewiring Technical Information Local touch panel and mobile terminal control Replace the traditional switch retain the o...

Страница 2: ...0mm 75mm 38mm Installation Instructions PRODUCT INSTALLATION CAUTION Cut off power supply at circuit breaker or fuse before installation to avoid fire or shock Neutral and live wire are required to put into the bottom box 1 As shown in Fig 1 using the screwdriver to pry the gaps on the side of the switch then open the panel Fig 1 2 Using both hands to hold the switch panel and forcibly push up to ...

Страница 3: ...n screw up to make it fixed on the wall Put the base to the wall as well as cover and press the touch panel Fig 3 Operation NETWORK ENTRY 1 Please follow the below menu order on APP to find the network join interface Log in Menu bar Device Management Add device 2 Connect the power supply and make sure that device in a state of No node ID 3 Press and hold any key on the panel for 8 seconds INDICATI...

Страница 4: ...peat steps 2 5 If the device Online directly perform steps 1 5 Offline disconnect the device first and then perform steps 1 5 Safety Notice A qualified electrician with the understanding of wiring diagrams and knowledge of electrical safety should complete installation following the instructions Before installation please confirm the real voltage complying with the device s specification Cut off a...

Отзывы: