![Hioki RM3542-50 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/hioki/rm3542-50/rm3542-50_instruction-manual_2137361095.webp)
7.1 Connecting the Printer
89
7
Before connecting the printer
Compatible printer
The requirements for a printer to be connected to the instrument are as follows.
Confirm compatibility and make the appropriate settings on the printer before connecting it to
the instrument.
See:
"7.2 Setting the Instrument" (p. 91)
• Interface ................................ RS-232C
• Characters per line ................ At least 45
• Communication speed........... 9600 bps
• Data bits ................................ 8
• Parity ..................................... none
• Stop bits................................. 1
• Flow control ........................... none
Printing
Chapter 7
Printing (p. 93)
• Measurement values and
comparator judgments
• Statistical calculation
results
Connecting the printer
to the instrument
Setting the
Instrument (p. 91)
Make printer
settings
7.1 Connecting the Printer
Because electric shock and instrument damage hazards are present, always follow
the steps below when connecting the printer.
•
Always turn off the instrument and the printer before connecting.
•
A serious hazard can occur if a wire becomes dislocated and contacts another con-
ductor during operation. Make certain connections are secure.
• As much as possible, avoid printing in hot and humid environments. Otherwise, printer life
may be severely shortened.
• Use only compatible recording paper in the printer. Using non-specified paper may not only
result in faulty printing, but printing may become impossible.
• The recording paper may jam if it move at angle relative to the roller.
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......