![Hioki RM3542-50 Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/hioki/rm3542-50/rm3542-50_instruction-manual_2137361099.webp)
7.3 Printing
93
7
Before Printing
Verify that the instrument and printer settings (p. 91) are correct.
Printing by key operation
Press the
key to print the measurement value currently displayed on the Measurement
screen.
Printing by external control
Measurement values and comparator judgments can be printed when the PRINT signal (the instru-
ment's EXT. I/O connector) is set to Low (ON) (shorted with ISO_GND
*
).
* ISO_GND is one of the pins of the instrument's EXT. I/O connector.
When statistical calculation is enabled [STATISTICS: ON] and triggering source is set to internal triggering
[TRG: INT], statistical calculations are performed and measurement values are printed. When external [TRG:
EXT] triggering is selected, only measurement values are printed. Use the TRIG signal to perform statistical
calculations with external triggering.
Statistical calculation results can be printed when auto-memory or statistical calculation is enabled
[ON]. To print, select PRINT on the screen or set the PRINT signal (the instrument's EXT. I/O con-
nector) to Low (ON) (shorted with ISO_GND
*
).
To enable auto-memory:
See:
"6.2 Store as soon as Measurement is Stable (Auto-Memory Function)" (p. 81)
To enable statistical calculation:
See:
"6.3 Performing Statistical Calculations on Measurement Values" (p. 84)
If no valid data exists, only the data set is printed. When only one valid data set exists, standard deviation of
sample and process capability index cannot be printed.
7.3 Printing
Printing Measurement Values and Comparator Judgments
Printing Statistical Calculation Results
(When statistical calculation is enabled)
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......