Hioki IM7580A-1 Скачать руководство пользователя страница 1

EN

Communication Instruction Manual

IMPEDANCE ANALYZER

Sept. 2016  Revised edition 2

 

IM7585A987-02  16-09H

IM7581

IM7580A

IM7585

IM7583

IM7583-01      
IM7583-02

IM7585-01
IM7585-02

IM7580A-1      
IM7580A-2

IM7581-01
IM7581-02

IM7587

IM7587-01
IM7587-02

Содержание IM7580A-1

Страница 1: ...struction Manual IMPEDANCE ANALYZER Sept 2016 Revised edition 2 IM7585A987 02 16 09H IM7581 IM7580A IM7585 IM7583 IM7583 01 IM7583 02 IM7585 01 IM7585 02 IM7580A 1 IM7580A 2 IM7581 01 IM7581 02 IM7587 IM7587 01 IM7587 02 ...

Страница 2: ...USB Settings and Connection 7 Setting USB 7 Connecting the USB Cable 8 2 3 LAN Settings and Connection 9 LAN Settings 9 Connecting a LAN Cable 13 2 4 GP IB Connection and Settings when the Z3000 is connected 14 Connecting the GP IB Cable 14 Setting GP IB 14 2 5 RS 232C Connection and Settings when the Z3001 is connected 16 Connecting the RS 232C Cable 16 Setting RS 232C 17 2 6 Remote Mode 18 Cance...

Страница 3: ...Contents ii ...

Страница 4: ...o the operator or damage to the instrument or malfunction IMPORTANT Indicates information related to the operation of the instrument or maintenance tasks with which the operators must be fully familiar Indicates prohibited actions Indicates the action which must be performed Indicates the action which must be performed Menus commands dialogs buttons in a dialog and other names on the screen and th...

Страница 5: ...2 Safety Information ...

Страница 6: ...N 9 to 5 V OFF Handshake About Buffer Flow Control Control during Receiving Input Buffer Usage Amount 85 75 25 Buffer Space Send XON Send XOFF XON XOFF control When the data in the receive buffer exceeds 75 of the buffer XOFF 13H is sent and the controller is notified that there is not much space remaining in the buffer Processing of the data in the buffer continues and then XON 11H is sent and th...

Страница 7: ...ervice request functions RL1 Supports all remote local functions PP0 Parallel poll functions are not supported DC1 Supports all device clear functions DT1 Supports all device trigger functions C0 Controller functions are not supported Code used ASCII code 1 3 USB Specifications Connector Series B receptacle Compliance tandard USB2 0 Full Speed High Speed No of ports 1 Class Communication class Sup...

Страница 8: ...s possible GP IB communication when the Z3000 is connected p 14 Commands common to IEEE 488 2 1987 requirement can be used The instrument has been designed with reference to the following standard Reference standard IEEE 488 2 1987 RS 232C communication when the Z3001 is connected p 16 WARNING Always turn both devices OFF when connecting and disconnecting an interface connector Otherwise an electr...

Страница 9: ...ication Screen Displayed while Setting Interfaces When you set an interface the icon for the set interface is displayed on the right side of the screen When USB is set When GP IB is set When RS 232C is set When LAN is set ...

Страница 10: ...CD or our web site http www hioki com The USB driver is compatible with the Windows Vista 32 bit 64 bit version Windows 7 32 bit 64 bit version Windows 8 32 bit 64 bit version and Windows 10 32 bit 64 bit version operating systems Additionally do not put the computer into the sleep state while the instrument is connected to the computer Setting USB Procedure You can configure the setting from any ...

Страница 11: ...avoid faults do not disconnect or reconnect the USB cable during instrument operation Connect the instrument and the computer to a common earth ground Using different grounds could result in potential difference between the instrument and the computer Potential difference on the USB cable can result in malfunctions and faults Do not disconnect or connect other USB devices from or to respectively P...

Страница 12: ...etting 0 0 0 0 can be kept as is Network Environment Configuration Example 1 Connecting the instrument to an existing network Example 1 Connecting the instrument to an existing network When connecting the instrument to an existing network the network settings need to be confirmed in advance An IP address which is not the same as that of another network device needs to be assigned Confirm the follo...

Страница 13: ...dure You can configure the setting from any of mode and mode 1 LCR Measurement Screen Interface Settings 2 LAN Settings Press 3 LAN Settings Select the IP address 4 IP address Settings or to set the IP address Press to confirm the setting ...

Страница 14: ...00 255 224 000 000 255 255 224 000 255 255 255 224 240 000 000 000 255 240 000 000 255 255 240 000 255 255 255 240 248 000 000 000 255 248 000 000 255 255 248 000 255 255 255 248 252 000 000 000 255 252 000 000 255 255 252 000 255 255 255 252 254 000 000 000 255 254 000 000 255 255 254 000 255 000 000 000 255 255 000 000 255 255 255 000 Initial setting 7 LAN Settings Select the default gateway If ...

Страница 15: ...ss to confirm the setting 9 LAN Settings Select the port number 10 Port number Settings or to set the port number to use for communication commands Settable range 1024 to 65535 Press to confirm the setting 11 LAN Settings Select the terminator setting CR LF CR 12 Press to confirm the setting ...

Страница 16: ...compliant straight through cable with cross over adapter up to 100 m Hioki 9642 LAN Cable option SPEED LED On Green 1000BASE On Orange 100BASE Off 10BASE LINK UP LED On Link up Off Link down Blinking Sending or receiving data The MAC address of the LAN is displayed below the serial number You can also check it on the instrument screen See Checking the Version of the Instrument in the instruction m...

Страница 17: ...hen the Z3000 is connected Connecting the GP IB Cable Connect the GP IB cable to the GP IB connector Recommended cable 9150 02 GP IB connection cable 2 m Setting GP IB Procedure You can configure the setting from any of mode and mode 1 LCR Measurement Screen Interface Settings 2 GPIB Setting Press ...

Страница 18: ...15 GP IB Connection and Settings when the Z3000 is connected 3 GPIB Setting Use or to set the GP IB address Select the terminator setting LF with EOI LF with CR EOI 4 Press to confirm the setting 2 ...

Страница 19: ...mpatible with the connectors on both the instrument and the controller The I O connector is a DTE Data Terminal Equipment configuration 1 2 3 4 5 6 7 8 9 Connector D sub Pin No Interchange Circuit Name CCITT Circuit No EIA Abbreviation JIS Abbreviation Common Abbreviation 1 Unused 2 Received Data 104 BB RD RxD 3 Transmitted Data 103 BA SD TxD 4 Data Terminal Ready 108 2 CD ER DTR 5 Signal Ground 1...

Страница 20: ...igure the setting from any of mode and mode 1 LCR Measurement Screen Interface Settings 2 RS 232C Settings Press 3 RS 232C Settings Select the terminator setting CR LF CR Select the baud rate setting Select the handshake setting No flow control Software XON XOFF control 4 Press to confirm the setting 2 ...

Страница 21: ...the mode becomes remote mode remote operation state and the keys on the LCD are disabled Remote Mode State All of the keys except are disabled Canceling Remote Mode Procedure 1 Local State Press to return to the normal state local state 2 LCR Measurement Screen The measurement screen is redisplayed ...

Страница 22: ...you connect the instrument to a computer and set its interface to USB it will be recognized as a virtual COM port on the computer Device Manager starts Check the COM number to the right of HIOKI USB Device in the Ports COM LPT list The procedure to start Device Manager differs depending on the version of the Windows operating system For details refer to Help of the operating system 10 9 8 7 6 5 4 ...

Страница 23: ...付2 Checking the USB Virtual COM Port ...