35
3
3
Specifications
3.1
General Specifications
Operating environment
Indoors, pollution degree 2, altitude up to 2000 m (6562 ft.)
Operating temperature
and humidity
−25°C to 65°C (−13°F to 149°F), 90% RH or less (no condensation)
Storage temperature
and humidity
−30°C to 70°C (−22°F to 158°F), 90% RH or less
(no condensation, when batteries are removed)
Dustproof and
waterproof
IP20 (Measuring voltage or current in a hazardous live conductor while
completely dry)
IP50 (Measuring resistance or current in an insulated conductor while completely
dry, or during storage)
However, the instrument’s handle provides IP54-equivalent dust and water
protection when the instrument is not making a measurement.
Standards
Safety
EN 61010
EMC
EN 61326
Power supply
LR03 alkaline battery ×2
Rated supply voltage: 1.5 V DC ×2
Continuous operating
time
Approx. 48 hours (Bluetooth communication OFF)
Approx. 24 hours (Bluetooth communication ON)
Other conditions: 100 A AC measurement, LCD backlight OFF, at 23°C (73.4°F),
for reference