3.   OPERATING TRANSMITTER:

A. 

 Store the transmitter away from excess heat or humidity.

B.

  Remove cover by snapping off from top or bottom, install 12V battery located in the wall transmitter, Duracell MN21/Eveready A23/GP  

      23A all 12V. (Fig. G)

      

NOTE:

 To prevent damage to the transmitter, remove these batteries if not used for long periods of time (months).

C.

  Operation buttons on the panel of the transmitter: (Figure G)

      HI button - for fan high speed.

      MED button - for fan medium speed.

      LOW button - for fan low speed.

      FAN OFF button - for fan speed off.

      OFF-ON Slide Button-This button turns the power Off and On to the Fan and Light(s).

      

      The

"LIGHT"

 button: This Button will control the light brightness. The light function is controlled by pressing the "

LIGHT

" button. Hold 

      the button down to increase or decrease the light. Tap the button quickly to turn the light off or on. If you press the button in excess of 0.7 

      seconds it  becomes a dimmer. The light varies cyclically in 0.8 seconds. The light key has auto resume, so it  will stay at the same  

      brightness as the last time it was turned off.

      

Fig. C

Fig. D

Fig.G

Fig.H

WALL

CONTROL

BLACK

BLACK

BLACK

BLACK

BLACK

WHITE

BLUE

B

LU

E

GROUND

GROUND

GREEN

INPUT

AC120V

AC SUPPLY

BLACK

BLACK

B

LA

C

K

WHITE

WHITE

W

H

IT

E

GREEN

YOUR REMOTE NOW HAS FULL CONTROL OF THE FAN AND LIGHT.
4.   TROUBLESHOOTING GUIDE  

      

A.  Fails to operate:    

      a.  Power to the receiver?   

      b.  Receiver wired correctly?   

      c.  Fan manual speed control in highest position? 

      d.  Light kit switch turned on?     

      e.  Code set at exact same position in both transmitter and  receiver?            

      

B.  Won't operate at distance:  

   .

    If transmitter operates the fan and the light kit when up close, but not a 30 feet 

away.

NOTICE!

Your ceiling fan and light kit assembly must meet 

the following requirements:

1.   Do not use with solid state fans.

2.   Electrical rating: 120V / 60 Hz

      MAX. motor amps:1.0 A

      MAX. light watts: 250 W 

      (Incandescent only)

For Warranty Information please visit 

www.hinkley.com

HI

MED

LOW

FAN OFF

LIGHT

23AE 12V

Remote pairing process:

NOTE:

 The ”FAN OFF” button must be pressed within 60 seconds of restoring power.

With the fan’s power off, restore power to the fan. Press and hold “FAN OFF” button for about 5 seconds and release. If optional

light kit is installed, the light kit will flash twice and the signal light on the handheld remote will come on when the button is

pressed. The fan has completed the pairing process with the handheld remote and is ready for use.