INSTALLING THE LED ASSEMBLY AND GLASS SHADE

1

2

3

4

5

NOTE: 

Be sure the power is off before installing.

Remove one of the three screws on the adapter plate located 

on the fan motor. Loosen the other 2 screws. (Do not remove) 

(Fig. 2)

While holding the LED assembly under your fan, make the 

polarized plug connections: (Fig. 2)

- Red to white

- Black to black

Tuck connections neatly into adapter plate. Place the key 

holes on the LED assembly over the 2 screws previously 

loosened, turn the LED assembly until it locks in place at the 

narrow section of the key holes. Secure by tightening the 2 

screws previously loosened and the one previously removed. 

Raise the glass shade against the LED assembly and turn 

clockwise until snug, DO NOT OVERTIGHTEN. 

Restore power and your LED assembly is ready for operation.

Fig. 2

Screws

Light 

assembly

Wire connectors

Содержание VENTUS

Страница 1: ...52 VENTUS CEILING FAN INSTRUCTION MANUAL INDOOR LED FAN LED ...

Страница 2: ... installation and operation of this fan It has been designed to make the installation process as easy as possible If you are unfamiliar or uncomfortable with wiring please contact a qualified electrician If you need additional assistance or have any questions please reach out to us For warranty information visit hinkley com SERVICE HINKLEY COM 800 HINKLEY LET S SEE THAT HINKLEY STYLE HINKLEY HINKL...

Страница 3: ...Y PRECAUTIONS 03 TOOLS MATERIALS REQUIRED 04 UNPACKING YOUR FAN 05 PREPARATION 05 INSTALLING THE HANGING BRACKET 06 HANGING THE FAN 08 ELECTRICAL CONNECTIONS FINISHING THE INSTALLATION 09 INSTALLING THE BLADES 10 INSTALLING THE MONTING PLATE 10 11 INSTALLING THE LED ASSEMBLY AND GLASS SHADE 12 INSTALLING THE WALL CONTROL 14 16 16 17 17 18 OPERATION CARE AND CLEANING TROUBLESHOOTING ENERGY GUIDE SP...

Страница 4: ... the carton until ready to be installed to protect its finish If you are installing more than one ceiling fan make sure that you do not mix fan blade sets as each blade is part of a weighted set After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the common conductor and the grounding conductor...

Страница 5: ...03 Disconnect power by removing fuse or turning off circuit breaker before installing the fan and or optional lighting Support directly from building structure To reduce the risk of fire electric shock or personal injury mount to outlet box marked acceptable for fan support and use mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixtures are no...

Страница 6: ... Hanging Bracket 3 Ceiling Canopy and Trim Ring 4 5 6 7 8 9 10 11 12 13 Downrod Asm Yoke Cover Fan Housing with Motor Remove rubber shipping supports around motor if applicable Save the screws Blade Arm Set of 3 16W LED Assembly Glass Shade Adapter Plate Hardware Bag Bracket Mounting Hardware wood screws screws lock washers star washers flat wasers wire nuts Blade to Blade Arm Screws w Fiber Washe...

Страница 7: ...rical shock be sure electricity is turned off at the main power box before wiring All wiring must be in accordance with National and Local Electrical Codes and the ceiling fan must be grounded as a precaution against possible electric shock Locate ceiling joist where fan is to be mounted being sure location agrees with the requirements in the minimum clearance section of this guide Wood joists must...

Страница 8: ...res come out facing upward Loosen the two security set screws and remove the downrod pin instead of hitch pin from the coupling on top of the motor assembly Fig 2 Carefully feed the electrical lead wires and safety cable from the fan through the downrod Thread downrod into coupler until holes align Insert downrod pin through holes in mounting collar and downrod clip cotter pin through small hole i...

Страница 9: ...nections refer to section titled Electrical Connections Slide canopy up and fasten to hanger bracket with 4 screws provided Fig 3 Ground Wire Hook up 3 Wires Downrod Cross pin Hanger ball Set screw Top of Fan Body Yoke cover Canopy Trim Ring Safety Cable Fig 4 INSTALLATION OF SAFETY SUPPORT Attach the lag bolt and flat washer to ceiling joist Attach the safety cable to lag bolt Slide cable clamp o...

Страница 10: ...nnections Fig 2 Connect the black hot wire from the ceiling to the black wire marked AC in L from the receiver Connect the white neutral wire from the ceiling to the white wire marked AC in N from the Receiver Secure the wire connections with the plastic wire nuts provided REMEMBER Turn off the power NOTE Control must be installed within 30 feet of fan WARNINGS Check to see that all connections ar...

Страница 11: ...section of the key holes Align the circular hole on canopy with the remaining hole on the mounting bracket secure by tightening the two set screws NOTE Adjust the canopy screws as necessary until the canopy and trim ring are snug Canopy Screws Trim Ring Ceiling Fan Outlet Box Hanger Bracket Groove WARNING Make sure the hook on the hanging bracket properly sits in the groove in the hanger ball befo...

Страница 12: ...of the adapter plate Place the key holes on the adapter plate over the 2 screws previously loosened turn the adapter plate until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Fig 1 Mounting Hub bottom of motor Adapter plate Light Wires Screws Blades Screws Fiber Washers Place Fiber washer on screw Inser...

Страница 13: ... connections Fig 2 Red to white Black to black Tuck connections neatly into adapter plate Place the key holes on the LED assembly over the 2 screws previously loosened turn the LED assembly until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Raise the glass shade against the LED assembly and turn clockw...

Страница 14: ...ote transmitter will be held in place with built in magnets Remove the existing wall plate and the old switch from the wall outlet box Seat the cradle A into the wall plate Fig 2 Connect the black lead wires from the switch in the cradle A to the black wires in the switch box Hot input wire to one of the cradle A switch leads Power lead to the fan is connected to the remaining switch lead Connect ...

Страница 15: ...he fan is connected to the remaining switch lead Fig 4 Attach the cradle A to the wall switch box using the supplied hardware Attach the multi gang faceplate to the switch set in the wall outlet box Cradle A of Hinkley switch will fit in any standard decora face plate Remote transmitter will be held in place with built in magnets 1 2 3 4 5 Option 3 Multi Gang Wall Switch Box Installation Fig 4 Out...

Страница 16: ...e been swallowed or placed inside any part of the body seek immediate medical attention The batteries shall be disposed of properly including keeping them away from children Even used cells may cause injury HIRO Control System 1 2 3 4 5 button Press this button and release instantly to turn on or off the light button Press and hold to dim or brighten lights to the desired level and release button ...

Страница 17: ...eration Make sure switch is not stuck between forward and reverse positions Summer Mode forward A DOWNWARD airflow creates a cooling effect as shown in Figure 3 This allows you to set your air conditioner on a warmer setting without affecting your comfort Winter Mode Reverse An UPWARD airflow moves warmer air off the ceiling area as shown in Figure 4 This allows you to set your heating unit on a c...

Страница 18: ...all electrical connections 3 Assure there are no more than 2 fans operating on a circuit through the wall control Assure that there are no more than 12 fans operating on a circuit through an on off wall switch or a breaker not through a wall control 4 Assure that the fan in within range of the WiFi 150 ft or wall control 30 ft 1 Allow a 24 hour breaking in period Most noise associated with a new f...

Страница 19: ... use 3 34 Cost Range of Similar Models 19 84 9 Estimated Yearly Energy Cost All estimates based on typical use excluding lights Airflow Shown Is a Weighted Average of High and Low Cubic Feet per Minute Based on Downrod ENERGY GUIDE SPECIFICATIONS AVERAGE PERFORMANCE AND ENERGY INFORMATION PERFORMANCE SPECIFICATIONS STANDARD HIGH SPEED LOW SPEED Airflow CFM Energy Use Watts Airflow Efficiency CFM W Ene...

Страница 20: ...recommended Factory Reset Method a Turn mains power OFF to the fan b Turn mains power back ON on the fan c Hold down the Power button on the transmitter for 5 seconds until the fan light flashes 3 times d Repeat steps a c above 4 more times e The fan s memory is now totally overwritten and it has forgotten all other remotes Brute Force Method https bondhome io app HINKLEY SMART FAN OPTIONS In addi...

Страница 21: ...UCTS THAT ENHANCE YOUR SPACE WITH COMFORT PURPOSE AND STYLE AS A FAMILY COMPANY WE ARE COMMITTED TO DESIGN PERFORMANCE AND QUALITY AND WHAT S IMPORTANT TO YOU IS PARAMOUNT TO US FOR A COMPLETE ASSORTMENT OF OUR PRODUCTS AND SOURCE BOOKS VISIT HINKLEY COM ...

Страница 22: ...GLOBAL HEADQUARTERS 33000 Pin Oak Parkway Avon Lake Ohio 44012 T 440 653 5500 F 440 653 5555 hinkley com ...

Отзывы: